SGM Giotto spot 1200 User Manual
SGM Giotto spot 1200 User Manual

SGM Giotto spot 1200 User Manual

Giotto spot 1200 professional moving head

Advertisement

G i o t t o s p o t 1 2 0 0
P r o f e s s i o n a l
M o v i n g
h e a d
User's Manual rel. 1.00

Advertisement

Table of Contents
loading

Summary of Contents for SGM Giotto spot 1200

  • Page 1 G i o t t o s p o t 1 2 0 0 P r o f e s s i o n a l M o v i n g h e a d User’s Manual rel. 1.00...
  • Page 2: General Instructions

    • Transport costs and related risks are borne by the fixture's owner. The guarantee is valid to all effects only on presentation of the guarantee certificate to the manufacturer or the nearest SGM technical assistance centre. • Always quote the unit's serial number and model when contacting your reseller for information or assistance.
  • Page 3: Table Of Contents

    3.16 - Control of the acceleration of movement speed 3.17 - DMX DLY 3.18 - SLLF 3.19 - Reserved functions 4 - Giotto Spot 1200 control channels 5- Iris channel -ch5 - 6 - Color channel - CH6- 7 - Gobo channel - CH7 -...
  • Page 4 Introduction Giotto Spot 1200 is an innovative professional SGM moving head fixture designed and built for use in large show events, thea- tres, TV studios and entertainment venues in general. The result of SGM's many years' experience in mechanical and electronic design, thanks to its avant-garde performance, Giotto Spot 1200 is one of the world's top fixtures.
  • Page 5: Main Features

    Main features Lamp Giotto Spots use a Philips MSR 1200SA 6500°K discharge lamp, without doubt the ideal light source for this type of fixture, as it combines reliability and long life (approximately 500 ) with astonishing luminous power. Effects - Iris - Linear 0÷100% dimmer - Shutter/Strobe from 1-10 fps - can run in music sync - Electronic focus...
  • Page 6 Accessories - Light Dome for outdoor protection cod: 0202406 - Single flight case cod: 0061741 - Double flight case cod: 0061744 - Optional clamp unit cod: 0202403...
  • Page 7: Technical Specifications

    47.5 WEIGHT: Kg 30 SGM Elettronica reserves the right to improve or modify their products at any time without prior notice. Always consult the handbook of the unit being used to avoid errors and differences between t he actual functions and those shown in the book.
  • Page 8: Installation

    Before proceeding with fixture installation, make certain that the packing contains all the items shown in the following list and ensure that the fixture is undamaged. If in doubt, don't use the fixture and contact an authorized SGM technical assistance centre and the freight company. In fact, only the recipient can claim for any damage caused to the fixture during transport.
  • Page 9: Lamp Alignment

    1.3 - Lamp installation ATTENTION! This fixture is designed exclusively for use with Philips MSR 1200SA lamps. NEVER USE ANY OTHER TYPES OF LAMPS. • Disconnect the power supply before carrying out any work on the fixture. • Make certain that the fixture is off and the temperature of the components can't cause burns (wait at least 20 minutes after switching off).
  • Page 10: Power Cable Construction

    1.5-Power cable construction DANGER! ELECTRICAL SHOCK HAZARD • Electrical work necessary for installing the fixture must be carried out by a qualified electrician or an experienced person. • The fixture must be suitably earthed. Failure to comply with this automatically invalidates the guarantee. The POWER-CON type connector supplied along with the Giotto is indispensable for connecting the fixture to the power supply.
  • Page 11: Positioning The Fixture

    1.8 - Positioning the fixture Can be installed in any position. down enter main power fuses Giotto 1200 m o v i n g h e a d w a s h l u m i n a i r e in/out dmx control GIOTTO REL.
  • Page 12 2.0-Construction of the signal cable Giotto 1200 has a DMX 512 input fitted with standard 5-pin XLR connectors. Screened cables in compliance with EIA RS- 485 specifications and the following characteristics must be used for connections: - 2 conductors plus screen - 120Ohm impedance - low capacitance - max.
  • Page 13: Rs-232 Connection

    2.2-RS232 connection For this connection, use good quality screened coax cable (RG58 50Ohms) to avoid problems with signal transmission and faulty fixture operation. Connectors must always be 5-pin XLRs. Refer to the diagram for wiring. E E N N Appendix...
  • Page 14: Navigating In The Menu

    3.0 - “Control” microcomputer Giotto Spot 1200 is equipped with a microcomputer which allows to customize the fixture to suite the type of installation. In fact, it's possible to assign the start address; obtain information regarding lamp life and fixture operation time; run test programs to check correct fixture operation and customize some parameters.
  • Page 15 Description Menu Options (Default configurations are shown in bold text) Addr=xxx Range 001-487 Addressing the fixture Pmove NORM Normal control of Pan from left to right Control of Pan inverted - from right to left. Sets Pan starting angle. PP_min Range 000-540 Default Configuration = 000 degrees Range 000-540 Sets Pan ending angle.
  • Page 16 3.2 - Allocating the first addressed channel In order to receive the commands necessary to operate from a lighting console, each fixture has to be allocated a start address. This address normally indicates the first channel used (start channel) and can be allocated following a different criterion from that used to connect the signal line.
  • Page 17: Limiting Tilt

    3.3 - Direction of Pan movement This function allows to decide the direction in which the Giotto's moving head pans, indispensable when several fixtures are installed in order that fixtures installed opposite each other move in the same direction when they receive a command.
  • Page 18: Lamp Elapsed Time Meter

    3.5 - Pan/Tilt inversion This function also allows to optimize the movement of the Giotto's moving head in relation to the operator's position, in order to simplify all positioning procedure. When SWAP is enabled (ON), this means that the lighting console sends the data regarding Pan to the Tilt con- trols and vice versa.
  • Page 19: Fixture Operating Time Meter

    3.8 - Fixture operating time meter This function allows to see for how many hours the fixture has been operating. This meter cannot be reset. To see for how many hours the fixture has been used, proceed as follows: Connect Giotto Spot to the power supply, wait till it has completed reset operations and “DMX signal” appears on the display.
  • Page 20: Display Brightness

    3.13 - Display brightness Operators can select one of the brightness levels available for the Giotto display, which can be standard or very low. This option is intended for theatre and television use, where excessive brightness can be troublesome. To change display brightness, proceed as follows: 1.
  • Page 21: Sllf

    3.18 - SLLF This is an energy-saving function. If the function is enabled (SLLF=ON), the fixture reduces lamp power by dim- ming it electronically after the shutter has been closed for 30 seconds. Maximum power will automatically be restored as soon as the shutter is reopened. To enable this function, proceed as follows: Connect Giotto Spot to the power supply, wait till it has completed reset operations and “DMX signal”...
  • Page 22: Giotto Spot 1200 Control Channels

    4.0 - GIOTTO SPOT 1200 CONTROL CHANNELS Functions Description Channel Pan High byte in 8-bit operation Pan MSB Only this byte is sent Pan Low byte for Pan LSB 16-bit positioning Tilt High byte in 8-bit Tilt Operation Only this byte is sent...
  • Page 23: Color Channel - Ch6

    6.0 - COLOR CHANNEL - CH 6- Giotto Spot 1200 is fitted with an exclusive color generation system comprising 12 frames containing dichroic colour fil- ters. Color changes are controlled by Channel 6, allowing to select 24 different colors which, combined with the two colour conversion filters, produce 72 different tones.
  • Page 24: Gobo Channel - Ch7

    7.0- GOBO CHANNEL - CH 7 Gobo selection is controlled by Channel 7. The gobo group comprises two independent wheels, each with four images and a blank position. The gobos are interchangeable and superimposing the two wheels enables 25 different combinations to be obtained. Changeover from one gobo to another can be done rapidly and directly, or blacked out: this function is controlled by chan- nel 8 (shutter/strobe) using the strobe/shutter's “Autoshade on Gobo”...
  • Page 25 8.0-CHANNEL SHUTTER/ STROBE CH - 8 The Shutter/Strobe is controlled by Channel 8. The mechanism which enables the strobe effect to be generated is the same as that used for dimming the light beam, however it's also possible to control the light's intensity while the strobe's enabled.
  • Page 26 10- GOBO ROTATION - CH 10 This channel is used to control the speed or positioning of the rotary gobos. Rotation can be in either direction at a speed which can be regulated from a minimum of 1.5rpm to a maximum of 40rpm, whereas a gobo's position can be set in a range of 360°.
  • Page 27: Electronic Focus - Ch 13

    13-ELECTRONIC FOCUS –CH 13- This channel gives smooth precise focus control, obtaining clear projections at any distance or suggestive out-of-focus effects. DMX 512 FUNCTION level Range 0-255 000 - 255 Linear Regulation 14-ADDITIONAL LENSES –CH 14- By means of this channel it's possible to choose projection angle from those available (see table). It's thus possible to obtain wide-angle projections at a short distance or long-throw projections.
  • Page 28 3 minutes. Lastly, Giotto Spot 1200 has another function which automatically reduces the power of the lamp by 50% every time the shutter or dimmer are closed. This function ensures considerable improvement in fixture cooling and increases lamp life.
  • Page 29 CONVERSION TABLE MSPEED MSPEED MSPEED MSPEED MSPEEDS VALUE SEC. VALUE SEC. VALUE SEC. VALUE SEC. VALUE SEC. VALUE E E N N Appendix...
  • Page 30 M 001235 SGM Elettronica srl Via Pio La Torre, 1 • 61010 Tavullia (PS), Italy Tel. +39 0721 476477 • Fax +39 0721 476170 e-mail: info@sgm.it • http://www.sgm.it...