All dimensions in millimeters and inches. Drawing not to scale This manual covers installation, use, and maintenance of the SGM Q Series. A digital version is available at www.sgmlight.com or upon request via support@sgmlight.com. The information in this document is subject to change without notice.
6 SAFETY INFORMATION 7 BEFORE INSTALLING THIS PRODUCT 8 INSTALLATION STANDARD FIXTURE 8 Identification and terminology 9 Unpacking 9 Application considerations 9 Transport & handling 9 Rigging 10 Rigging process using SGM Omega brackets 11 Tilt lock 11 Power requirements 12 Connecting power 12 Connecting data 12 Connecting a wireless transmitter 12 Signal priority 13 INSTALLATION POI FIXTURE 13 ...
Page 5
30 CONTROL MENU 32 RDM 32 Supported RDM functions 32 Sensors 33 ACCESSORIES 33 Barndoors 34 Anti-glare shields 34 Filter frames 35 MAINTENANCE 35 SGM Vacuum Test kit 36 Firmware Updates 37 Cleaning 37 Maintenance Schedule 37 Maintenance Notes 38 TROUBLESHOOTING 39 FIXTURES AND ACCESSORIES 39 Ordering information 40 SUPPORT HOTLINE...
WARNING! READ THE FOLLOWING SAFETY PRECAUTIONS CAREFULLY BE- FORE UNPACKING, INSTALLING, POWERING OR OPERATING THE DEVICE. SGM fixtures are intended for professional use only. They are not suitable for household use. Les fixtures SGM sont impropre à l’usage domestique. Uniquement à usage professionnel.
EXTERNAL CLEANING AND VISUAL INSPECTION OF THE FIXTURE All users of the SGM fixtures should regularly clean those parts of the fixture directly exposed to the elements, such as the external housing and front lenses. Additionally, all owners of the SGM fixtures must periodically check the external housing of the fixture for structural breaks, deteri- oration, cracked lenses, or loose screws.
Ø 18 mm All SGM fixtures have locking points in the base for installation and rig- [ 0,7in ] ging. In both standard and POI fixtures, the distance between the points from center to center is always 106 mm.
Ø18 Omega bracket 233,80 467,60 Figure 2: Dimensions for base locking points RIGGING PROCESS USING SGM OMEGA BRACKETS Holes for omega bracket Omega bracket Figure 3.1 : Omega bracket attachment Figure 3.2 : Base with Omega brackets WARNING! ALWAYS USE MIN. 2 OMEGA BRACKETS WHEN RIGGING THE FIXTURE.
5. Install a safety wire that can bear at least 10 times the weight of the fixture. The safety wire attachment point is designed to fit a carabiner AISI316 grade. 6. Verify that there are no combustible materials, cables, or surfaces to be illuminated within 0.3 m (12 in) of the fixture.
IP-rated XLR connectors suitable for outdoor use. Terminate the DMX out cable of the last fixture in the data link with a 120 ohm DMX termination. Note that SGM fixtures provide a passive DMX Thru signal as DMX Out, instead of an active output signal. PLEASE NOTE! FOR POI VERSIONS, PLEASE REFER TO “INSTALLATION POI FIXTURE”...
INSTALLATION POI FIXTURE IDENTIFICATION AND TERMINOLOGY A: RGBW LED panel B: POI Tilt Lock C: Cooling Fans LED Indicator (POI only) E: Rubber feet F: GORE-TEX Membrane G: Power in and out H: DMX in and out I: Handle J: Barndoors attachment points (x2) K: Safety wire attachment point L: Holes for Omega brackets / M-10 screws (x6) Illustrations might vary from received products.
PLEASE NOTE! POI FIXTURES SHOULD BE PRE-SET WITH ANY CUSTOM PROGRAMMING BEFORE INSTALLATION ALTHOUGH MOST FUNCTIONS ARE POSSIBLE TO BE SET VIA RDM ONCE MOUNTED IN POSITION, IT IS EASIER TO DO CONFIGURATION AND ANY TROUBLESHOOTING BEFORE MOUNTING IS COMPLETE. UNPACKING Unpack the device and inspect it to ensure that it has not been damaged during transport.
CONNECTING TEMPORARY SIGNAL The fixture is compatible with DMX512 (ANSI E1.11 – 2008) only. It can be connected using either the SGM POI up-load- er cable, or via the fixture’s built-in CRMX wireless receiver system. STEP 1: Download and install the SGM RDM Addressing tool.
POI fixture. But on POI, these settings are changed through the Addressing Tool. Figure 10: SGM Addressing tool STEP 1: Launch SGM RDM Addressing Tool. Click Full Discovery and look for the green light to illuminate on the fixture. If the green light does not appear, cycle power or refer to troubleshooting.
In order to do so, make sure the fixture is powered on be- fore taking the following steps: STEP 1: Using a SGM magnetic spanner tool, place the mag- net close to the LED indicator, and wait for 3 seconds. The LED indicator will blink orange for 1-2 seconds, before switching to static green again.
MOUNTING All SGM POI fixtures have M10 size attachment points to mount the supplied brackets or directly to a structure. The POI wash fixture may be installed in any orientation and it might take up to two brackets per fixture. Depending on the structure, please use appropriate and secure methods for mounting the Omega brackets.
FLAT BRACKET ATTACHMENT M10 Countersunk Bolts Flat Bracket 8mm or smaller screw or bolt to structure 8mm or smaller screw or bolt to structure Fixture OMEGA BRACKET ATTACHMENT M10 Stainless Steel Bolts 13mm / 0.5in hole diameter for attachment point POI Omega Bracket Fixture Product Version 1.0 | Revision D | Released 2022-06-20...
UNIVERSAL BRACKET ATTACHMENT Using a bolt through this slot, M10 Countersunk Bolts the fixture will rotate around its center point, always use 2 bolts with washers. POI Universal Bracket Using a bolt through this slot, the fixture will rotate around its center point, always use 2 bolts with washers.
WALL BRACKET ATTACHMENT Medium 6/8 Series Attach and align the bracket to a surface. The shorter side of the bracket is the side that attaches to a wall surface. There are two slots provided to align the bracket. Using appropriate fas- teners, align and level the bracket.
POI TILT LOCK The fixture can be tilted in any orientation. To adjust the tilt angle in POI fixtures: • Loosen the two tilt lock knobs (one on each side) by turning them counter-clockwise using the small pig-nose key. Knobs are loosened by turn- ing counter-clockwise.
DMX signal, like to RS-485 signal protocol. DMX in and DMX out are in the same cable. See more in figure above about the SGM POI DMX cable. For permanent installations, have a qualified electrician wire the mains cable directly to a suitable branch circuit.
In order to do so, make sure the fixture is powered on before taking the following steps: • STEP 1: Using a SGM magnetic spanner tool, place the magnet close to the LED indicator, and wait for 3 sec- onds. The LED indicator will blink orange for 1-2 seconds, before switching to static green again. The fixture can now be paired to a new transmitter.
DISPLAY OPERATIONAL MODE (A) Displays the current mode (quick color, stand-alone, or DMX mode). The fixture is set by default to be controlled in DMX mode. 6CH CTC MODE (107) DMX ADDRESS (B) A - Operational mode Displays the current DMX address. The DMX address is al- B - DMX address tered directly from this view.
CONFIGURING THE DEVICE FOR DMX CONTROL ABOUT DMX The fixture can be controlled using signals sent by a DMX controller on a number of DMX channels. DMX is the USITT DMX512-A standard, based on the RS-485 standard. The signal is sent as DMX data from a console (or a controller) to the fixtures via a shielded twisted pair cable designed for RS-485 devices.
SETTING A STATIC COLOR MANUALLY The standard fixture can be configured to display a predefined and static color. To set up a static color select ENTER → MANUAL → QUICK COLOR. Note that, once the MANUAL → QUICK COLOR settings are changed, the fixture will be set, by default, to automatical- ly start in quick color mode whenever it is powered on.
INDIVIDUAL FIXTURE SETTINGS Flipping the OLED display If the fixture is installed hanging upside down, it might be useful to flip the display so that it is easier to read. To flip the display, press ENTER and select SETTINGS → FLIP DISPLAY, or press the up and down buttons on the control panel at the same time.
Product Type Displays product type. Firmware Version Displays installed firmware version. Hardware Revision Serial Number Displays SGM serial#. RDM ID Displays RDM ID (Unique RDM ID for identification). DMX View Up to 504 DMX ad- Displays received DMX levels. dresses...
Page 31
LEVEL 1 LEVEL 2 LEVEL 3 FUNCTION Manual* Quick Color Editor Static quick color - red mix (0-255). Sets fixture to quick color startup mode. Green Static quick color - green mix (0-255). Sets fixture to quick color startup mode. Blue Static quick color - blue mix (0-255).
SUPPORTED RDM FUNCTIONS The Q-8 features are supported via various RDM functions. RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional commu- nication between the fixtures and the controller over a standard DMX line. This protocol will allow configuration, sta- tus monitoring and management.
ACCESSORIES BARNDOORS The Q-8 features 4-way and 8-way barndoors. The barndoors are designed and intended to be mounted on the fixture without the use of any tools. To install the barndoors: • Attach the lower plug-in pins to the bottom part of the Q-8 front.
Figure 25 : Half anti-glare shields FILTER FRAMES The Q-8 features various optional magnetic, holographic fil- ter frames such as elliptical diffusers. There are four filter frame choices available from SGM: • wide angle • medium angle • elliptical vertical wide angle •...
Figure 28: SGM Vacuum Test Kit USB - XLR UPLOADER CABLE The SGM USB to DMX cable is an accessory used mainly to update the fixture with the latest SGM firmware. See below how to update the fixture with the latest firmware.
• Click “Full Discovery” fixture should show in the chart. Firm- ware will be displayed in the firmware column To update a fixture with the latest firmware, use an SGM USB Figure 31: SGM Firmware tool 5-Pin-XLR uploader cable, and a Windows-based computer with the SGM Firmware Tool software installed (available for download at www.sgmlight.com).
CLEANING SGM fixtures with IP65 or IP66-rating do not need any cleaning procedures inside the fixture. However, cleaning the front lens may be needed to achieve the maximum light output after exposure to dust, sand, or dirt. The exterior housing can also be cleaned to get a better look. To maintain adequate cooling, fans must be cleaned periodically.
Confirm that the power is switched on, confirm to be completely dead. that the cables are plugged in. If the cause can- not be detected, contact your local SGM dealer or support@sgmlight.com Fixture suddenly turned off. Power was turned off.
Flight case for 4 pcs of P-6 / Q-8 incl. accessories P/N: 82051509 A-4 Art-Net to DMX converter P/N: 80070217 Power cable with IP connector P/N: 07860275 SGM USB uploader cable P/N: 83062011 Vacuum Test Kit P/N: 83061136 POI uploader cable P/N: 83062067...