Q-10 Connection Diagram; Using Standalone Operation; Setting A Static Color Manually - SGM Q Series User Manual

Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

Q-10 Connection diagram

100- 277V AC
50-60 Hz
1000W
XLR pin out
DATA
GND
DATA -
DATA +
Figure 12: Q-10 connection diagram (see "Q-10 POI connection diagram" on page 18 for POI version)

Using standalone operation

Standalone operation is not running when the fixture is connected to a control device, but when it is pre-programmed with a series
of up to 24 scenes, playing continuously in a loop. Up to three standalone programs can be defined and run from the menus, and
one of the programs can be set to run by default whenever the fixture is powered on.
Each of the three available standalone programs contains 24 user-definable
scenes with its own RGB and shutter settings.
Each scene has a definable fade-in time for the transition from one color to the
next, and a wait (static) time of up to 120 minutes and 59 seconds.
To define a standalone program, press ENTER → MANUAL → EDITOR.
The standalone mode of the fixture's startup is enabled by selecting:
ENTER → SETTINGS → STARTUP MODE → SELECT STARTUP MODE →
STANDALONE.
To select the fixture's startup program, press:
ENTER → SETTINGS → STARTUP MODE → STARTUP PROGRAM.
The chosen program will run its length cyclically whenever the fixture is
powered on.
To run an internal program, go to:
ENTER → MANUAL → RUN PROGRAM.
To stop an active internal program, go to:
ENTER → MANUAL → STOP PROGRAM.
Please note: In POI versions, configuring the fixtures can only be done through RDM.

Setting a static color manually

The Q-10 can be configured to display a predefined and static color.
To set up a static color select ENTER → MANUAL → QUICK COLOR.
Note that, once the MANUAL → QUICK COLOR settings are changed, the fixture is set, by default, to automatically start in quick color
mode whenever it is powered on. This can be reset through the menu SETTINGS → STARTUP MODE → SELECT STARTUP MODE.
The current quick color program can always be stopped by going to:
ENTER → MANUAL → STOP PROGRAM
See "Control menu" on page 14 for detailed information about the manual menu.
Please note: In POI versions, configuring the fixtures can only be done through RDM.
12
1
5 PIN XLR
2
Max. 32 units/DMX line
100- 277V AC
50-60 Hz
1000W
Figure 13: Standalone operation
XX
100- 277V AC
50-60 Hz
1000W
120 Ohm +/- 5%