Reduced Wiring Connector System - Omron F3SG RE Series User Manual

Safety light curtain
Hide thumbs Also See for F3SG RE Series:
Table of Contents

Advertisement

Wiring/Installation

4-5-4-4. Reduced Wiring Connector System

Reduced wiring can be achieved by using a Y-Joint Plug/Socket Connector (F39-GCNY1, sold separately).
When using the reduced wiring connector system, the Operating Range Selection is fixed to Long Mode.
 Y-Joint Plug/Socket Connector (F39-GCNY1, sold separately)
15.0
M12 IP67 connector, 4-wire
<Internal wiring diagram>
Connected to Single-Ended Cable or
Double-Ended cable
2
1
3
4
Male
Connected to Power Cable or
Double-Ended Cable of F3SG-RE Emitter
1
2
4
3
Female
Wrong wiring causes the F3SG-RE to go to the Lockout state due to Operating Range Selection Setting error.
Model
F39-GCNY1
F3SG-R
184
User's Manual
Plug marked with ● (blue circle): Connect to control panel side
Socket marked with ○ (open circle): Connect to emitter
17.7
45.5
CN2
To control
panel side
To emitter
CN1
M12 IP67 connector, 4-wire
+24 VDC
OSSD 2
0 VDC
OSSD 1
+24 VDC
Operating Range Select Input
0 VDC
Not used
L (m)
Insulated vinyl round cable dia. 6
500
Brown
White
Blue
Black
Brown
White
Blue
Black
0.5
40.7
To receiver
M12 IP67 connector, 4-wire
Material: PBT (Main body)
Connected to Power Cable or
Double-Ended Cable of F3SG-RE Receiver
1
1
2
2
3
4
3
4
Female
(Unit: mm)
M12 x 1