2-25. Operating Status Monitoring

F3SG-RA Series
F3SG-RE Series
2-25-1. Overview
I/O information and the state of F3SG-RA can be read out with the Configuration Tool. This function is
only for F3SG-RA Configuration Tool.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User's Manual for more
information on setting this function by the Configuration Tool.
The Operating Status Monitoring is not available for the F3SG-RE.
2-25-2. Readout Information
The user can view the following information related to a receiver.
The information is displayed in a block in case of a cascade connection.
External wiring
information
Sensor Information
Operating Status
F3SG-R
108
User's Manual
X
Information Name
Power Supply
OSSD 1 (Black)
OSSD 2 (White)
RESET (Yellow)
AUX (Red)
MUTE A (Gray)
MUTE B (Pink)
Scan code
EDM
Interlock/Pre-Reset
Fixed/Floating Blanking
PNP/NPN
DIP Switch/Configuration Tool Displays DIP Switch/Configuration Tool setting
Muting information
Override information
Sequence error information
Safety output information
Blanking beam unblocked
information
Push-SW information
Description
Displays a supply voltage being supplied
Linked to safety output 1
Linked to safety output 2
Linked to Reset/External Device Monitoring (EDM)/Override Input
Linked to auxiliary output
Linked to Muting input A
Linked to Muting input B
Displays Scan Code setting
Displays EDM setting
Displays Interlock/Pre-Reset setting
Displays Fixed/Floating Blanking setting
Displays output mode (PNP/NPN) setting
Linked to Muting state
Linked to override state
Linked to Muting sequence error state or Interlock sequence error state
Linked to safety output
Linked to the state where the blanking beam is unblocked
Linked to the input signal of Push Switch