Manuals and User Guides for Omron MiniSafe 4800 Series. We have
2
Omron MiniSafe 4800 Series manuals available for free PDF download: Installation And Operating Manual
Omron MiniSafe 4800 Series Installation And Operating Manual (61 pages)
Safety Light Curtains 5-Pin Version
Brand:
Omron
| Category:
Lighting Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
Section 1 -- Important Safety Warnings
8
Section 2 -- Significant Features
9
MS4800 Series Features
9
System Components and Indicators
9
Figure 2-1 MS4800 Access to Features
9
Figure 2-2 System Components
10
Table 2-1 System Components Identification
10
Section 3 -- System Operation
11
Operating States
11
Machine Run
11
Machine Stop
11
Interlock
11
Alarm
11
Operating Modes
11
Automatic Start
12
Start/Restart Interlock
12
MSF4800 Cascaded Series
12
MSF4800 Requirements
12
MSF4800 Segment Reduction Restart Procedure
13
Figure 3-1 Cascaded MSF4800
13
Section 4 -- Detection Options
14
Fixed Blanking
14
Figure 4-1 Adding Hard Guarding to Light Curtain When Using Fixed Blanking
14
Selecting Fixed Blanking with Selector Switches
15
Figure 4-2 Selecting Fixed Blanking Procedure 1
15
Table 4-1 Tolerance Effect of Fixed Blanked Area on Resolution
15
Figure 4-3 Selecting Fixed Blanking Procedure 2
16
Figure 4-4 Selecting Fixed Blanking Procedure 3
16
Figure 4-5 Selecting Fixed Blanking Procedure 4
16
Figure 4-6 Selecting Fixed Blanking Procedure
17
Figure 4-7 Selecting Fixed Blanking Procedure
17
Floating Blanking
18
Selecting Floating Blanking with Selector Switches
18
Table 4-2 Diagram of Operation
18
Fixed Blanking with Floating Blanking
19
Resolution
19
Table 4-3 System Response to Floating Blanking
19
Table 4-4 Floating Blanking Effects on Resolution
19
Optical Synchronization
20
Table 4-5 Sample S and D
20
Table 4-6 Sample S and D
20
Table 4-7 Sample S and D
20
Table 4-8 Sample S and D
20
Pf Factors for MS4800-14 System
20
Pf Factors for MS4800-20 System
20
Pf Factors for MS4800-30 System
20
Pf Factors for MS4800-40 System
20
Section 5 -- Diagnostic and Test Features
21
Individual Beam Indicators
21
External Device Monitoring (EDM) - also Known as MPCE Monitoring
21
Range Selection
21
Table 4-9 Synchronization Requirements
21
Section 6 -- Using Selector Switches to Set Features
22
Manual Selector Switch Version
22
Access to the Selector Switches
22
Transmitter Selector Switch Settings
22
Figure 6-1 MS4800S Selector Switches
22
Figure 6-2 Transmitter Selector Switches
22
Table 6-1 Transmitter Selector Switch Settings
22
Receiver Selector Switch Settings
23
Operating Mode Selection
23
Selecting and Programming Fixed Blanking
23
Selecting Floating Blanking
23
Selecting Scan Codes
23
Figure 6-3 Receiver Selector Switch Settings
23
Table 6-2 Receiver Selector Switch Settings
23
Section 7 -- Outputs
24
Safety Outputs
24
Section 8 -- Safe Mounting Distance
25
Safety Distance Formulas
25
Figure 8-1 Safe Mounting Distance
25
European Safety Distance Formulas
26
Safety Distance Formula for Systems with a Minimum Object Resolution of 40 MM or
26
Less
26
Safety Distance Formula for Systems with a Minimum Object Resolution Greater
26
Than 40 MM
26
Factors Affecting the Safety Distance Formula
27
Section 9 -- Installation
28
Reflective Surface Interference
28
Figure 9-1 Worst Case Alignment Example
28
Figure 9-2 Unsafe Mounting Example (1)
28
Figure 9-3 Unsafe Mounting Example (2)
28
Cross Talk Mitigation
29
Figure 9-4 Correct Mounting Example with Proper Alignment
29
Figure 9-5 Minimum Distance from a Reflective Surface as a Function of Range
29
General Mounting Considerations
30
Additional Guarding
30
Added Mounting Rigidity
30
Figure 9-6 Correct Light Curtain Installation Example
30
Figure 9-7 Adding Mounting Bracket
30
Installation of Multiple Systems
31
Detection Zone
31
Alignment
31
Input Power Requirements
31
Figure 9-8 Multiple Light Curtain Installation Configurations
31
Figure 9-9 Multiple Light Curtain Installation Configurations Using Scan Codes
31
Requirements for Perimeter Guarding
32
Marking Minimum Object Resolution
32
Presence Sensing Device Initiation
32
Section 10 -- Connecting to the Machine Control Circuit
33
Connecting to a Safety Monitoring Device
34
Figure 10-1 Connecting to a Safety Monitoring Device
34
Connecting Via an RM-1 Module
35
Figure 10-2 Connecting Via an RM-1 Module
35
Connecting Via an RM-2AC Module
36
Figure 10-3 Connecting Via an RM-2AC Module
36
Connecting Via Two Force-Guided Relays
37
Figure 10-4 Connecting Via Two Force-Guided Relays
37
Connecting Via an RM-2AC-IP
38
Figure 10-5 Connecting Via an RM-2AC-IP Module
38
Section 11 -- Checkout and Test Procedures
39
Checkout Procedure
39
Test Procedure
39
Using the Test Object
39
Figure 11-1 Test Object Pattern
39
Section 12 -- Cleaning
40
System Specifications
41
Table 13-1 System Specifications
41
Section 13 -- Specifications and Additional Information
42
Cable Lengths (Customer Supplied Cables)
42
Table 13-2 Response Time of MS/MSF4800 System
42
Table 13-3 MS4800 Input & Output Signal Cable Lengths
42
Minisafe MS4800 Dimensional Drawings
43
Figure 13-1 MS4800 Dimensional Drawing
43
Table 13-4 MS4800-14/20 Transmitter and Receiver Dimensions
44
Table 13-5 MS4800-30 Transmitter and Receiver Dimensions
45
Table 13-6 MS4800-40 Transmitter and Receiver Dimensions
46
Minisafe Cascaded MSF4800 Dimension Drawings
47
Figure 13-2 MSF4800 Dimension Drawings
47
Table 13-7 MSF4800-14/20 Transmitter and Receiver Dimensions
48
Table 13-8 MSF4800-30 Transmitter and Receiver Dimensions
49
Table 13-9 MSF4800-40 Transmitter and Receiver Dimensions
50
Warranty
51
Patents
51
Trademarks
51
Repairs
51
Documentation Criteria
52
Compliance with Rohs
52
Section 14 -- Glossary
53
Section 15 -- Diagnostics & Troubleshooting
54
Diagnostics
54
Table 15-1 Diagnostic Codes
54
Receiver Diagnostic Information
56
Receiver Endcap Indicator Lights
56
Receiver Troubleshooting
56
Figure 15-1 Example of IBI Led's Used to Show Fault Code
56
Troubleshooting the Transmitter
57
Appendixa -Checkout Procedure
58
Appendixb -Test Procedure
59
Advertisement
Omron MiniSafe 4800 Series Installation And Operating Manual (26 pages)
Safety Light Curtains
Brand:
Omron
| Category:
Safety Equipment
| Size: 1 MB
Table of Contents
Table of Contents
11
Table 2-1 Feature Comparison
14
Table 3-1 System Components Identification
15
Table 5-1 Tolerance Effect of Fixed Blanked Area on Resolution
21
Table 5-2 - Diagram of Operation
24
Table 5-3 - System Response to Floating Blanking
25
Table 5-4 Floating Blanking Effects on Resolution
25
Table 5-5 Possible Blanking Function Combinations
25
Table 5-6 - Sample S and D
26
Table 5-7 - Sample S and D
26
Table 5-8 - Sample S and D
26
Table 5-9 - Sample S and D
26
Advertisement
Related Products
Omron F3S-A082P
Omron F3S-A161P
Omron F3S-A162-U
Omron F3S-A162P
Omron F3S-A242P
Omron F3S-A321P
Omron F3S-A322P
Omron F3S-A402P
Omron F3S-A481P
Omron F3S-A482P
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL