2-21-1. Overview
A lamp (F39-LP and F39-BTLP, sold separately) can be connected to a receiver and turned ON based
on the operation of F3SG-RA. The lamp can indicate red, orange, and green colors, to which three
different states can be assigned. When there are several illumination conditions, the priority of the
colors to illuminate or blink is red > orange > green.
Usage Example:
• Indicate that F3SG-RA is in muting or override
• Indicate that F3SG-RA is under lockout
Indicate that a machine is stopped (safety output is in the OFF state)
Refer to the instruction sheet of the Lamp for more information.
The lamp is not intended to be used for the emitter. Do not connect the lamp to the emitter.
The Lamp is not available for the F3SG-RE.
2-21-2. Factory Default Setting
The factory default setting is Red as inverted signal of the safety output information, Orange as
inverted signal of the stable-state information and ON 1 time*, Green as the safety output information.
* Refer to Output pattern chart below.
2-21-3. Setting with DIP Switch
The user cannot make any changes to this function by the DIP Switch.
2-21-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.