5-2-3-2. Manual Reset Mode, EDM enabled and NPN Outputs

The following is the example of Muting not used, External Device Monitoring enabled, Manual Reset
mode, NPN output and External Test in 0 V Active.
[DIP Switch settings] *2
EDM Enabled
Receiver
Manual Reset
NPN
Emitter
External Test: 0 V Active
Configure functions with the DIP Switches before wiring.
[Wiring Example]
F39-JG A-L
S1
+24 VDC
Power Supply
0 VDC
Function
F39-JG A-D
S2
KM1
KM2
S1: Test Switch (Connect the line to 24 V if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
*1. Also used as EDM input line.
*2. The functions are configurable with DIP Switch. Refer to
Chapter 3 Setting with DIP Switch for more information on
setting the functions by the DIP Switch.
Unblocked
Beam state
Blocked
Test Switch (S1)
Reset Switch (S2)
OSSD
Input/Output Circuit and Applications
DIP-SW1
DIP-SW2
: Indicates a switch position.
KM1
KM2
KM1
KM2
M
E
F3SG-R
205