Omron F3SG RE Series User Manual page 163

Safety light curtain
Hide thumbs Also See for F3SG RE Series:
Table of Contents

Advertisement

 Side Mounting
Standard Fixed
Bracket
(F39-LGF)
Standard Fixed
Bracket
(F39-LGF)
F3SG-RE30 Series
Dimension A
4-digit number of the type name
Dimension C1
(Protective height)
Dimension D
C1-50
Dimension P
Protective height
Number of Standard
(C1)
Fixed Brackets *1
0190 to 1230
2 *2
1310 to 2270
3
2350 to 2510
4
*1. The number of brackets required to mount either one of emitter and receiver.
*2. Mounting an emitter or receiver with one bracket is possible for the models of protective height of 0160 to 0270. In this case, locate this bracket
at half the Dimension A (or at the center of the sensor length).
4-4-3-1. Mounting with Standard Fixed Brackets (F39-LGF)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described
above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- The Standard Fixed Bracket does not allow beam alignment.
40
35
C1
20
Dimension F
1000 mm max.
1000 mm max.
1000 mm max.
35
2-M5 or M6
2-M5 or M6
9.2
42.35
< Screw: M5 or M6 >
F3SG-RE14 Series
Dimension A
C2+30
4-digit number of the type name
Dimension C2
(Protective height)
Dimension D
C2-20
Dimension P
10
Protective height
Number of Standard
(C2)
Fixed Brackets *1
0160 to 1200
2 *2
1280 to 2080
3
Wiring/Installation
[ Unit : mm ]
Dimension F
1000 mm max.
1000 mm max.
F3SG-R
139
User's Manual
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg ra seriesF3sg r series

Table of Contents