Safety light curtain
Hide thumbs Also See for F3S-A P Series:

Advertisement

Quick Links

Safety Light Curtain
Space-saving, Self-contained Design
Requires No Control Box
Meets OSHA, Canadian, and worldwide
H
standards for safeguarding personnel from
moving machinery
Self-contained design with no control box
H
UL and CSA Listed
H
Beam spacing of 10 or 20 mm
H
(0.39 or 0.79 in)
Protective height ranges from 140 to 940
H
mm (5.51 to 37.0 in)
Connect multiple units for a larger protected
H
zone
M12 connector
H
Ordering Information
J SAFETY LIGHT CURTAINS
Shape, detection distance
Extension cable (required)
Detection distance:
5 m (16.40 ft.)
Protective
height
Beam spacing
of 10 mm
M12 connector
Extension cable (required)
Arrow.com.
Downloaded from
R
Beam
Minimum
spacing
detectable
object
10 mm
15 mm in
(0.39 in)
diameter
(0.59 in)
Number
of beams
of beams
(This table continues on the next page.)
No. of
Protective height
beams
(n)
16
150 mm (5.9 in)
32
310 mm (12.2 in)
48
470 mm (18.5 in)
F3S-Aj j j j P
Part number
F3S-A161P
F3S-A321P
F3S-A481P

Advertisement

Table of Contents
loading

Summary of Contents for Omron F3S-A P Series

  • Page 1 F3S-Aj j j j P Safety Light Curtain Space-saving, Self-contained Design Requires No Control Box Meets OSHA, Canadian, and worldwide standards for safeguarding personnel from moving machinery Self-contained design with no control box UL and CSA Listed Beam spacing of 10 or 20 mm (0.39 or 0.79 in) Protective height ranges from 140 to 940 mm (5.51 to 37.0 in)
  • Page 2 F3S-Aj j j j P F3S-Aj j j j P Ordering Information Table -- continued from previous page Shape, detection distance Beam Minimum No. of Protective height Part number spacing detectable beams object 20 mm 25 mm in 140 mm (5.5 in) F3S-A082P Extension cable (required) diameter...
  • Page 3: Specifications

    F3S-Aj j j j P F3S-Aj j j j P Specifications J RATINGS AND PERFORMANCE Part number F3S-A161P F3S-A321P F3S-A481P F3S-A082P F3S-A162P F3S-A242P F3S-A322P F3S-A402P F3S-A482P No. of beams Protective height 150 mm 310 mm 470 mm 140 mm 300 mm 460 mm 620 mm 780 mm...
  • Page 4 F3S-Aj j j j P F3S-Aj j j j P Specifications Table -- continued from previous page Part number F3S-A161P F3S-A321P F3S-A481P F3S-A082P F3S-A162P F3S-A242P F3S-A322P F3S-A402P F3S-A482P Ambient Incan- 3,000 lx max. (receiver surface light intensity) light descent intensity lamps Sunlight 10,000 lx max.
  • Page 5: Engineering Data

    F3S-Aj j j j P F3S-Aj j j j P Engineering Data J OPERATING RANGE F3S-A481P (10-mm beam spacing) F3S-A481P (10-mm beam spacing) (Parallel to Center Line of Lenses) (Perpendicular to Center Line of Lenses) Distance X (m) Distance X (m) F3S-A482P (20-mm beam spacing) F3S-A482P (20-mm beam spacing) (Parallel to Center Line of Lenses)
  • Page 6: Operation

    F3S-Aj j j j P F3S-Aj j j j P Operation J CIRCUIT DIAGRAM This reference diagram focuses on internal circuitry. External device connections indicate functions available, and are not to be used for installation. +24 V Brown External diagnosis input∗...
  • Page 7 F3S-Aj j j j P F3S-Aj j j j P J TIME CHART The output transistor will be OFF for a maximum of 210 µs, as shown in the following table, in order to perform output circuit self-diagno- sis when the Light Curtain is receiving light. The width and number of OFF signals are determined by the number of Light Curtains connected in series.
  • Page 8 F3S-Aj j j j P F3S-Aj j j j P Dimensions Unit: mm (inch) J SAFETY LIGHT CURTAINS F3S-Aj j j j P 14.5 (0.57) A complete F3S-AjP sys- tem is shown at left. No sepa- rate controller is required. 2-φ6.5±...
  • Page 9 F3S-Aj j j j P F3S-Aj j j j P Unit: mm (inch) J MOUNTING BRACKETS Mounting Brackets (Top and Bottom) (0.55) 32.3 (1.27) (0.37) (0.22) 7 (0.28) 6 (0.24) 30.6 (0.39) (1.42) (1.20) (0.79) (0.39) 6 (0.24) 7 (0.28) (0.08) U-shaped bracket Marking for...
  • Page 10: Extension Cables

    F3S-Aj j j j P F3S-Aj j j j P J ACCESSORIES Extension Cables F39-JA1C (L = 3 m) F39-JA2C (L = 7 m) F39-JA3C (L = 10 m) For Emitter 14.9 dia. 6-dia. vinyl -insulated round cable with Waterproof connector four conductors (12/0.18 dia.) and four conductors (7/0.2 dia.) Standard length (L): 3, 7, and 10 m...
  • Page 11: Installation

    Before installing safety light curtain, read and follow directions in Installation Manual provided with product. If you do not have an installation Manual, do not proceed with installation until you have obtained it from Omron Electronics, Inc. J WIRING Use the following diagram to wire an interface to the light curtain.
  • Page 12: Parallel Connection

    F3S-Aj j j j P F3S-Aj j j j P Parallel Connection DANGER Use the required interface with captive contact safety relays at the beginning of this section. When using 1 set only, connect F3S-AjP as shown as below. Emitter 1 and Receiver 1 (gray and gray/black are open). When connecting 3 sets or more in parallel, connect the gray and gray/black of Receiver 1 with those of Emitter 2, and connect others in the same way of Emitter 2 and Receiver 2 in the figure.
  • Page 13: Series Connection

    F3S-Aj j j j P F3S-Aj j j j P Series Connection Connect the F3S-AjP as shown below with the optional Series Connection Cable (F39-JA1B). DANGER Use the required interface with captive contact safety relays at the beginning of this section.
  • Page 14 F3S-Aj j j j P F3S-Aj j j j P Connection Example with a G9S Safety Relay Unit Reset switch KM1, KM2: Electromagnet contactor (LP1D) KM3: Solid-state contactor (G3J) 3-phase motor 24 VDC Power Supply (S82K) E1 can be mounted on F3S-A only 24-VDC Power Supply (S82K) PLC: Programmable Logic Controller...
  • Page 15: Incorrect Installation

    F3S-Aj j j j P F3S-Aj j j j P Precautions WARNING J INSTALL CORRECTLY Do not use the F3S-AjP on a machine that cannot be stopped Correct Installation by electrical control in an emergency. Dangerous machine parts can be reached only by passing through J CALCULATING THE SAFETY DISTANCE the F3S-AjP detection zone.
  • Page 16 • Mount a capacitor with a minimum 47-nF capacity and • minimum 630 V voltage rating between the 0V line and PE. Recommended Power Supplies: S82K, S8PS, S82J or S82H • made by OMRON. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com. Arrow.com.
  • Page 17 NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ON- -LINE OMRON ELECTRONICS LLC OMRON CANADA, INC. One East Commerce Drive 885 Milner Avenue Global - - http://www.omron.com Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8 USA - - http://www.omron.com/oei 1-800-55-OMRON 416-286-6465 Canada - - http://www.omron.com/oci...