• If the input subsystem sample frequency is slower than the selected input frequency, then
the new measure count value is stored as each period measurement completes. When an
input subsystem sample occurs, then the most recently stored measure count is written
into the input data stream.
When the selected start edge is not the same as the selected stop edge, the internal 48 MHz
counter starts incrementing when it detects the selected start edge and stops incrementing
when it detects the next selected stop edge; at that point, the counter stores and resets the
count. The stored count is maintained until it is read as part of the input data stream or until a
new count is stored. The value of the measure count depends on the input subsystem sample
frequency, described as follows:
• If the input subsystem sample rate is faster than the selected measurement period, then
the stored count retains the current value when the count is read by the input subsystem.
• If the input subsystem sample rate is slower than the selected measurement period, then a
new count value is stored as each period measurement completes. When an input
subsystem sample occurs, the most recently stored measure count is written into the input
data stream.
A data pipeline is used in the hardware to compensate for the A/D group delay and
synchronizes the value of the measure counters with the analog input measurements, so that
all measurements are correlated in time. The measure counters are treated like any other
channel in the analog input channel list; therefore, all the triggering and conversion modes
supported for analog input channels are supported for the measure counters.
When you read the value of the measure counters as part of the analog input data stream, you
might see results similar to the following:
Table 4: An Example of Reading a Measure Counter as Part of the Analog Input Data Stream
Time
A/D Value
10
5002
20
5004
30
5003
40
5002
50
5000
60
5002
70
5004
80
5003
90
5002
Measure Counter
Values
0
Operation started, but is not complete
0
Operation not complete
0
Operation not complete
12373
Operation complete
12373
Next operation started, but is not complete
12373
Operation not complete
12373
Operation not complete
14503
Operation complete
14503
Next operation started, but is not complete
Status of Operation
Principles of Operation
101