Strobe Output - Photon Focus MV1-D2048-3D03 Series User Manual

3d cmos camera with gige interface
Table of Contents

Advertisement

Edge Triggered Trigger Acquisition
The Edge Triggered mode is enabled by setting TriggerAcquisition_Mode to Edge and
TriggerAcquisition_Enable=True. Two signals act as trigger enable (see Fig. 5.36). A rising edge
on the start signal enables triggering. A rising edge on the stop signal disables all triggers. The
start/stop signals are selected by TriggerAcquisition_StartSource and
TriggerAcquisition_StopSource.
6 r i g g e r A c q u i s i t i o n _ S t a r t
T r i g g e r A c q u i s i t i o n _ S t o p
I n t e r n a l T r i g g e r E n a b l e
T r i g g e r I n
A p p l i e d T r i g g e r
Figure 5.36: Trigger Acquisition Level triggered (TriggerAcquisition_Mode = Edge)
Trigger Acquisition and Free-Running Trigger
The TriggerAcquisition feature can also be used with free-running trigger (TriggerMode=Off).
TriggerAcquisition enables or disables in this case the generation of the free-running trigger.

5.4.12 Strobe Output

The strobe output is an isolated output located on the power supply connector that can be
used to trigger a strobe. The strobe output can be used both in free-running and in trigger
mode. There is a programmable delay available to adjust the strobe pulse to your application.
The strobe output needs a separate power supply. Please see Section 6.6, Fig.
5.23 and Fig. 5.24 for more information.
MAN052 12/2018 V3.2
@ i s a b l e d
e n a b l e d
5.4 Trigger and Strobe
d i s a b l e d
73 of 131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv1-d2048-3d04 series

Table of Contents