Trigger And Strobe Signals For Gige Cameras; Overview - Photon Focus MV1-D2048-3D03 Series User Manual

3d cmos camera with gige interface
Table of Contents

Advertisement

6.6 Trigger and Strobe Signals for GigE Cameras

6.6.1 Overview

The 12-pol. Hirose power connector contains two external trigger inputs, two strobe outputs
and two differential inputs (G2 models: RS-422, H2 models: HTL). All inputs and outputs are
connected to the Programmable Logic Controller (PLC) (see also Section 6.7) that offers
powerful operations.
The pinout of the power connector is described in Section A.1.
G2 models: ISO_INC0 and ISO_INC1 RS-422 inputs have -10 V to +13 V extended
common mode range.
H2 models: The voltage level for the HTL interface should be given by the user by
means of connecting the encoder power pin (HTL_ENC_PWR) and the ISO_PWR
pin to the same power supply within a range between 10 and 30V. In the same
way, encoder ground (HTL_ENC_GND) and ISO_GND signals should be connected
to the same ground in order to guarantee the good reception of the differential
signals.
ISO_OUT0 and ISO_OUT1 have different output circuits (see also Section 6.6.2).
A suitable trigger breakout cable for the Hirose 12 pol. connector can be ordered
from your Photonfocus dealership.
Simulation with LTSpice is possible, a simulation model can be downloaded from
our web site www.photonfocus.com on the software download page (in Support
section). It is filed under "Third Party Tools".
Don't connect single-ended signals to the differential inputs ISO_INC0 and
ISO_INC1.
Fig. 6.4 shows the schematic of the inputs and outputs for the G2 models and Fig. 6.5 for the
H2 models. All inputs and outputs are isolated. ISO_VCC is an isolated, internally generated
voltage.
.
MAN052 12/2018 V3.2
6.6 Trigger and Strobe Signals for GigE Cameras
89 of 131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv1-d2048-3d04 series

Table of Contents