(3) If red indicator keeps flashing:
Check if the battery connection is reversed.
Check if there is any short circuit on the output connection.
Check if the environment temperature is too low (0
The battery charger may be defective if the red indicator continues to flash.
(4) Charging indicator (orange) cannot turn to green:
The battery might be defective, please stop charging and have the battery be repaired.
(5) If the charging indicator (orange) turns to green (fully charged) immediately:
The battery may be in well-charged condition.
The battery may be defective if the battery is not fully charged.
Warning! The charger should only be used in a dry interior. Protect from moisture and wetness.
Forbidden! Although the travel scooter has passed the required IPX4 water spray test requirements, keep electrical
connections away from sources of moisture, including direct exposure to water or body fluids, and incontinence. Check
the electrical components frequently for signs of corrosion and replace if necessary.
6. CAUTION
(1)
Before using the battery charger, read all instructions and cautionary markings.
(2)
Use the battery charger in a well-ventilated area
(3)
To avoid the risk of injury, charge only lead-acid or gel cell type rechargeable batteries.
(4)
Please turn off the power after charging
(5)
Plug the off-board charger power cord into the charger port during battery charging.
o
C)
Off-Board Charger Port
The off-board charger port
is mounted on the tiller.