Power Over Ethernet Status - Planet WGS-4215-T User Manual

Table of Contents

Advertisement

• PD Class
• Current Used [mA]
• Power Used [W]
• Power Allocation
Buttons
: Click to apply changes.

4.15.4 Power over Ethernet Status

This section provide per port PoE status and the
The priority is used in case the total power consumption is over the total power
budget. In this case the port with the lowest priority will be turned off, and offer
power for the port of higher priority.
Displays the class of the PD attached to the port, as established by the
classification process. Class 0 is the default for PDs. The PD is powered based
on PoE Class level if the system is working in Classification mode. The PD will
return to Class 0 to 4 in accordance with the maximum power draw as specified
by
Table
4-15-1.
The Power Used shows how much current the PD currently is using.
The Power Used shows how much power the PD currently is using.
It can limit the port PoE supply watts. Per port maximum value must be less
than 36 watts. Total port values must be less than the Power Reservation value.
Once power overload is detected, the port will auto shut down and keep in
detection mode until PD's power consumption is lower than the power limit
value
screen in
Figure 4-15-5 Power over Ethernet Status Screenshot
344
User's Manual of WGS Managed Series
Figure 4-15-5
appears.