Note:
Up to 4 rules can be configured.
8.
Click <Apply> to save the settings.

10.5 Region Entrance Detection

This function is not available in all models.
The <Region Entrance Detection> function detects people, vehicles or other objects which enter a pre-
defined virtual region from the outside place and certain actions can be taken when the alarm is
triggered.
Steps:
1. Enter the <VCA Settings> interface: Menu> Camera> VCA
2. Select the camera to configure the <VCA>.
You can click the checkbox of <Save VCA Picture> to save the captured pictures of <VCA Detection>.
3. Select the <VCA Detection Type> to <Region Entrance Detection>.
4. Check the <Enable> checkbox to enable this function.
5. Click
to configure the <Trigger Channel>, <Arming Schedule> and <Linkage Actions> for the
<Line Crossing Detection Alarm>.
6. Click the <Rule Settings> button to set the <Sensitivity> of the <Region Entrance Detection>.
<Sensitivity>: Range [0-100]. The higher the value is, the more easily the <Detection Alarm> can be
triggered.
7. Click
and draw a Quadrilateral in the preview window by specifying four vertexes of the
detection region and right click to complete the drawing. Only one region can be configured.
Draw Area for Intrusion Detection