User Manual of Thermal Bi-spectrum Network Speed dome
alarm device.
E.g., select Alarm Rule as Above (Max. Temperature) and set the Alarm Temperature
to 40 °C, and the device alarms when the maximum temperature is higher than 40 °C.
Task 2.
For two alarm rules of area, you can set the alarm for area temperature difference.
a) Set the area alarm rules.
b) Click
difference alarm interface.
c) Select two rules to compare the saved areas.
d) Set the alarm rules and the temperature.
E.g., select Area 1 and Area 2, and set the comparison rule as Above (Max.
Temperature), and set the temperature difference threshold to 5 °C. The device
alarms when the difference of two areas' maximum temperature is above 5 °C.
e) Set the Alarm Output with the connected alarm sensor and alarm device.

5.4.3 Linkage Method

Purpose:
Set the linkage method of the alarm.
Steps:
1. Enter Configuration > Temperature Measurement > Linkage Method.
2. Set the arming schedule and linkage method.
Arming Schedule: Click on the time bar and drag the mouse to select the time period.
Linkage Method: Click Linkage Method and check the checkbox to select the linkage
method. Audible warning, notify surveillance center, send email, upload to FTP, trigger
channel and trigger alarm output are selectable. You can specify the linkage method
when an event occurs.
3. Click Save to save the settings.
After the settings, you can view the current temperature and humidity on the top of this
interface.
© Hikvision
Figure 5-31 Area Temperature Difference Alarm
to show the area temperature
65