OPEARTING MANUAL
Setup of the Lower limit of temperature range. The minimum difference between lower and upper limit is 20 K. If you set the
u
0.0
lower limit to a value ≥ upper limit the upper limit will be adjusted to [lower limit + 20 K] automatically.
Setup of the Upper limit of the temperature range. The minimum difference between upper and lower limit is 20 K. The upper
n 500.0
limit can only be set to a value = lower limit + 20 K.
Setup of the Lower limit of the signal output. This setting allows an assignment of a certain signal output level to the lower limit
[ 0.00
of the temperature range. The adjustment range corresponds to the selected output mode (e.g. 0-5 V).
Setup of the Upper limit of the signal output. This setting allows an assignment of a certain signal output level to the upper limit
] 5.00
of the temperature range. The adjustment range corresponds to the selected output mode (e.g. 0-5 V).
Setup of the Temperature unit [°C or °F].
U °C
Setup of the Lower alarm limit. This value corresponds to Alarm 1 [►5.6 Alarms] and is also used as threshold value for relay
| 30.0
1 (if the optional relay board is used).
Setup of the Upper alarm limit. This value corresponds to Alarm 2 [►5.6 Alarms] and is also used as threshold value for relay 2
|| 100.0
(if the optional relay board is used).
XHEAD
Setup of the Ambient temperature compensation. In dependence on the emissivity value of the object a certain amount of
ambient radiation will be reflected from the object surface. To compensate this impact, this function allows the setup of a fixed
value which represents the ambient radiation.