OPEARTING MANUAL
Temperature range (scalable)
Ambient temperature (head)
Storage temperature (head)
Spectral range
Optical resolution
System accuracy
1) 2) 3)
1) 3)
Repeatability
4)
Temperature coefficient
NETD
3) 5)
Response time (95 % signal)
Warm-up time
Emissivity/ Gain
Transmissivity
Signal processing
1)
at ambient temperature 23 5 °C; whichever is greater; at object temperatures ≥ 20 °C; response time=1s
2)
Accuracy for thermocouple output: ±2,5°C or ±1%
3)
ε = 1
4)
for ambient temperatures (head) <18 °C and >28 °C; whichever is greater-
5)
at time constant 100 ms and an object temperature of 25 °C
6)
with dynamic adaptation at low signal levels
Technische Änderungen vorbehalten
0141 0315-100
17.08.2015
2MH
385...1600 °C
490...2000 °C
-20...125 °C
-40...125 °C
1,6 µm
75:1
90 mK
0,100...1,100 (adjustable via programming keys or software)
0,100...1,100 (adjustable via programming keys or software)
Average, peak hold, valley hold (adjustable via programming keys or software)
B+B Thermo-Technik GmbH | Heinrich-Hertz-Str. 4 | D-78166 Donaueschingen
Fon +49 771 83160 | Fax +49 771 831650 | info@bb-sensors.com | bb-sensors.com
2MH1
3ML
50...400 °C
22:1
±(0,3 % TMeas +2°C)
±(0,1 % TMeas +1 °C)
±0,05 K/ K or ±0,05 %/ K
160 mK
600 mK
1 ms
10 min
3MH
1)
100...600 °C
1)
-20...85 °C
-40...125 °C
2,3 µm
33:1
60 mK
18 / 88