If multiple faults are detected, the number of faults will
appear in the corner of the telltale icon (A).
Using the HPT scroll/select knob, select the question
mark symbol next to the short description to display a
detailed description of the fault. If there are multiple faults,
the icons (A) will appear in a row. To display a detailed
description of each fault, use the HPT scroll/select knob to
select the icon.
3.17.3 Setting up the Harvest Performance Tracker (HPT) Screen
The setup menu configures the HPT for specific operations. The following settings should be checked before initial
operation of the windrower.
The key must be turned to the ON position to enter the setup menu, but the engine does not have to be running.
Setting Screen Brightness and Volume
Setting Screen Brightness:
The screen brightness is shown with a 10-segment bar graph and is adjustable down to 10%. The brightness
automatically adjusts for daytime and nighttime operation. Day mode is defined as having the headlights or work
lights OFF (or having only the clearance lights ON). Night mode is defined as having either the headlights or work
lights ON.
214053
OPERATOR'S STATION
Figure 3.91: Telltale Icon (Multiple Faults
Detected)
Figure 3.92: HPT Fault Description Page
89