Troubleshooting Harvest Performance Tracker - M1 Series Windrower Only - MacDon D2 Series Operator's Manual

Draper header for windrowers
Hide thumbs Also See for D2 Series:
Table of Contents

Advertisement

5.7.2 Troubleshooting Harvest Performance Tracker – M1 Series Windrower Only
The harvest performance tracker (HPT) provides is the diagnostic information for the electronic timed double-knife system.
It displays any error codes received from the electronic timed double knife module. The tables below describe the error
codes.
Check the Input/Output page for diagnostic information.
Table 5.6 Controller Error Codes
Error ID
SPN
FMI
1.1
521517
1.2
1.3
521518
1.4
1.5
1.6
1.11
1.12
1.7
521519
1.8
1.9
521520
1.10
214509
MAINTENANCE AND SERVICING
SPN
Short Fault Text
Description
1
ETDK
Controller
2
1
ETDK
Temperature High
Controller
2
CPU Temperature
3
4
5
Firmware Fault
6
1
ETDK
Controller Vref
2
1
ETDK
Controller
Output
2
Low Battery
Battery voltage is low. Contact dealer to check
Voltage
charging system
High Battery
Battery voltage is high. Contact dealer
Voltage
Module has exceeded max operating temperature.
Allow module to cool down before continuing
operation.
Module has exceeded max operating temperature.
High
Allow module to cool down before continuing
operation.
Memory Fault
Controller memory failure detected. Contact
dealer
Memory Fault
Corrupt data detected. Contact dealer
Firmware failure detected. Contact dealer
Timer Fault
Module timer fault has been detected. Please
restart module. If issue persists, please contact
dealer.
Low Voltage
Reference voltage low error. Check wiring for
damage. The following sensors may be affected:
LH knife speed, RH knife speed, knife pressure
sensor (header sensor)
High Voltage
Reference voltage high error. Check wiring for
damage. The following sensors may be affected:
LH knife speed, RH knife speed, knife pressure
sensor (header sensor)
Low Voltage
Low voltage on circuit. Check wiring for damage.
Contact Dealer The following valves may be
affected: LH knife bypass valve, RH knife bypass
valve
Over Current
High current on circuit. Check wiring for damage.
Contact dealer The following valves may be
affected: LH knife bypass valve, RH knife bypass
valve
241
Long Fault Text
Revision A

Advertisement

Table of Contents
loading

Table of Contents