I User Functions - Zodiac HPO Instructions For Installation And Use Manual

Table of Contents

Advertisement

• Reduce the temperature setpoint to below the water temperature to check that the heat pump stops operating.
• Switch off the heat pump by pressing

2.4 I User functions

2.4.1 "Automatic keypad lock" function
The "automatic keypad lock" function allows the keypad to be disabled when inactive for a certain period of time to
prevent mishandling.
Locking/unlocking the keypad:
• Press
+
simultaneously for 5 seconds.
The
indicator appears (= locked) or disappears (= unlocked) depending on the keypad's state.
2.4.2 Changing operating mode
The heat pump can operate in "HEATING", "COOLING" or "HEATING & COOLING" (automatic regulation) mode.
Information: "HEATING" mode
• When "HEATING" mode is selected, the heat pump heats the pool water to the temperature setpoint.
• The heat pump stops automatically once the temperature setpoint is reached.
Information: "COOLING" mode
• When "COOLING" mode is selected, the heat pump cools the pool water to the temperature setpoint.
• The heat pump stops automatically once the temperature setpoint is reached.
Information: "HEATING & COOLING" mode (automatic regulation)
• When the "HEATING & COOLING" operating mode is selected, the heat pump automatically switches to
"HEATING" mode (if the water temperature falls ≤ -1°C below the temperature setpoint) or to "COOLING"
mode (if the water temperature rises ≥ +2°C above the temperature setpoint) in order to maintain the
pool at the temperature setpoint.
Example: When the temperature setpoint is 28°C, if the water temperature rises to 30°C, the heat
pump will automatically switch to "COOLING" mode to return to the temperature setpoint. If the water
temperature falls to 27 °C, the heat pump will automatically switch to "HEATING" mode to return to the
temperature setpoint.
To switch to "HEATING", "COOLING" or "HEATING & COOLING" (automatic control) mode:
• Press
for 5 seconds to select "HEATING", "COOLING" or "HEATING & COOLING" (automatic regulation) mode.
The corresponding indicator lights up to indicate the mode selected.
In "HEATING & COOLING" mode (automatic regulation), the 2 indicators
2.4.3 Configuring the temperature setpoint
Begin by selecting the desired operating mode: "HEATING" , "COOLING" or "HEATING & COOLING" (automatic
regulation) using the
key.
• Press
or
, the setpoint value of the previously selected operating mode will flash.
• Press
to increase the temperature by 1°C,
• Press
to reduce the temperature by 1°C.
• Press
to confirm and exit "configuration" mode.
and check that it stops.
and
are lit.
EN
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpo-6Hpo-8Hpo-9Hpo-11Hpo-14Hpo-18

Table of Contents