152-202-116-02, Issue 2
P
ROVISIONING
The H2TU-C-202 List 1F can be provisioned by accessing the HiGain HDSL2 maintenance screens
page
9). The maintenance screens are accessed through a maintenance terminal (ASCII terminal or a PC running
terminal emulation software) connected to the H2TU-C craft port (or to an HMU craft port). This gives you full
access to all H2TU-C status, history, inventory, and provisioning screens.
All configuring is accomplished through the maintenance terminal screens with the exception of the bidirectional
(NLOC and CREM) loopback which is enabled or disabled by depressing the front-panel LBK pushbutton.
The H2TU-C-202 contains a non-volatile RAM (NVRAM) which stores the system option settings.
The settings are retained if shelf power is lost or if the H2TU-C-202 is unplugged.
U
M
SING A
AINTENANCE
Connecting to a Maintenance Terminal
The craft port on the front panel allows you to connect the H2TU-C-202 to a maintenance terminal (ASCII
terminal or PC running a terminal emulation program). Once connected to a maintenance terminal, you can access
the maintenance, provisioning, and performance screens.
To connect to a maintenance terminal:
1
Connect a standard 9-pin terminal cable to the RS-232 craft port
front panel.
2
Connect the other end of the cable to the serial port on the maintenance terminal.
3
Start a terminal emulation program such as ProComm (emulating a VT-100 terminal).
4
Configure the maintenance terminal to the following communication settings:
•
9600 baud
•
No parity
•
8 data bits
•
1 stop bit
•
Hardware flow control to OFF
5
If necessary, press
H2TU-C-202 List 1F
T
ERMINAL
CTRL
R
+
to refresh the HiGain HDSL2 logon screen.
March 14, 2000
(Figure 1 on page
3) on the H2TU-C-202
Provisioning
(Figure 3 on
7