Insert each FLC-704 CU into the COT Shelf and observe that all LEDs:
•
turn ON for approximately 2 seconds
•
scan from top to bottom
•
flash all ON, then OFF
If the LEDs do not follow the above sequence, see
2
Verify that the front panel indicators ACTIVE 1 through ACTIVE 8 and FAULT LEDs are all off when the
PG-Flex system has powered up, established HDSL synchronized communications, and no calls are in
progress.
To activate the ground start feature, use a List 3 of higher PG-Flex CO and RTLUs.
P
ROVISIONING
Provision the FLC-704 using the appropriate line unit technical practice. For each channel provisioned, select loop
start or ground start.
V
I
ERIFY
NSTALLATION
After the PG-Flex system is powered up and HDSL communication is synchronized:
1
Verify that the front panel ACTIVE indicators are all OFF and the FAULT indicator is OFF (no calls are in
progress).
2
Test the loop start circuits, as follows:
•
Place an outgoing call for each subscriber circuit provisioned, and verify that the ACTIVE LED tracks
the progress of the call (refer to
•
Place an incoming call to each subscriber circuit provisioned, and verify that the ACTIVE LED tracks
the progress of the call (refer to
3
Test the ground start circuits, as follows:
•
Place an outgoing call for each subscriber circuit provisioned, and verify that the ACTIVE LED tracks
the progress of the call (refer to
•
Place an incoming call to each subscriber circuit provisioned, and verify that the ACTIVE LED tracks
the progress of the call (refer to
FLC-704 List 4B
T
-
URN
UP
Table
10.
Table 1 on page 2
for front panel indications).
Table 1 on page 2
for front panel indications).
Table 1 on page 2
for front panel indications).
Table 1 on page 2
for front panel indications).