Parameter
27 SEnS
ESC
MODE
28 FCLO
ESC
MODE
Description
Enabling/disabling room sensor to acti -
vate pure climate control (thermoregula -
tion from a single external probe). Default
set to ON. This value can be set to ON or
OFF . In AUTO
operating modes only, by setting this
parameter to OFF the heating/cooling re -
quest is processed as follows:
− In ON/OFF mode, the heating/
cooling request is always active
(relay closed) if the T3 (comfort)
time period is active.
− In OTBus mode, the heating request
is always active (only with the ex -
ternal probe connected to the boil -
er or the external web probe via
the APP) and the heating setpoint
temperature is calculated using
the external probe value only. The
value set for parameter 26 (tSFt) is
subtracted from the heating de -
livery setpoint calculated by the
Hi, Comfort T100 (tSEt), only in AUTO
operating mode, during the
T2 (economy) or T1 (anti-freeze) time
period.
9
This
function
Hi, Comfort T100
Time display setting. Default set to 24-hour
clock.
The format can be set to the 12- or 24-hour
clock.
Setting the parameter to 12H, the field is
display in the 12-hour a.m./p.m. format.
70
, MAN
and PARTY
uses
only.