Setting The Operating Mode - Riello Hi, Comfort 100 Installer And User Manual

Table of Contents

Advertisement

9
If at least one Hi, Comfort T100
thermostat is in cooling mode, the
heating request via OTBus is not
considered.
3.5
Setting the operating
mode
From the HOME screen, press ESC/MODE
repeatedly
to select one of the following modes:
3.5.1
OFF mode
In OFF mode, the Hi, Comfort T100
guarantees the minimum room tem-
perature set at parameter 01 from the
PL technical menu only.
NOTE
Only if the boiler is in the correct oper-
ating condition (i.e. powered and not
blocked).
In case of an OTBus connection be-
tween the WiFi Box and the boiler (in-
cluding other types of connection via
OTBus), the boiler remains OFF if all the
Hi, Comfort T100 thermostats in the
system are OFF. When the boiler is OFF
it does not provide any heating or do-
mestic hot water.
RESET
3.5.2
Hi, Comfort T100 in SUMMER/DOMES-
TIC HOT WATER mode. In this mode, the
boiler provides domestic hot water
where requested (instant boiler).
If the parameter 24 CLOC is set to ON; the
Hi, Comfort T100 follows the time peri-
ods set in the user-programming menu
for DHW, pre-heating the water in the
storage tank (only for boilers with inte-
grated tank).
The minimum room temperature set
at parameter 01 from the PL technical
menu is, however, guaranteed.
ESC
In case of an OTBus connection between
MODE
the WiFi Box and the boiler (including
other types of connection via OTBus),
the boiler remains in SUMMER mode
if at least one of the thermostats is in
summer mode and the others are OFF.
SET
PROG
RESET
48
SUMMER/DHW mode
ESC
MODE