NetVanta 950 IAD Hardware Installation Guide
Rack mounting the NetVanta 950
The NetVanta 950 can also be rack mounted in either a 19" or 23" equipment rack using an optional
mounting kit. Rackmount kits can be purchased separately for installation in standard 19" rack (P/N
1200799L19) or a standard 23" rack (P/N 1200799L23). Follow these steps to mount the NetVanta 950
into a rack.
Be careful not to upset the stability of the equipment mounting rack when installing this
product.
Step
1.
Attach the rackmount ears to the NetVanta 950 chassis (see Figure 11).
2.
Position the NetVanta 950 in a stationary equipment rack. To allow proper grounding, scrape
the paint from the rack around the mounting holes where the NetVanta 950 will be positioned.
3.
Have someone else hold the unit in position as you install two mounting bolts through the unit's
brackets and into the equipment rack using a Phillip's screwdriver.
4.
Proceed to the steps given in Installing Modules and Grounding Instructions on page 28 and
Supplying Power to the Unit section on page 29.
The NetVanta 950 IAD system is intended to be installed, maintained, and serviced by
qualified personnel only.
61200788L1-34B
Instructions for Rack Mounting the NetVanta 950
Figure 11. Rack Mounting the NetVanta 950 IAD