List Of Parameters - DeDietrich 24 Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 24:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 144
en
9 Settings
9.2

List of parameters

Tab.115 Table of parameters
Name
Description
Operation of contact X15 (also see setting AP098)
1: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code H02.10)
2: Contact open —> Heating, domestic hot water dis­
AP001
abled (error code H02.09)
3: Contact open —> Heating, domestic hot water and
antifreeze disabled (error code E02.13 with reset re­
quest)
Manual heating request enabled based on implemen­
tation of setting AP026
AP002
0: Disabled
1: Enabled
Notification of low pressure in the heating installation
AP006
[bar]
Hours of burner ignition before the maintenance noti­
AP009
fication with AP010=1
Enables/disables maintenance notifications:
0: No notification
AP010
1: Customised notification (depending on settings
AP009 and AP011)
2: ABC service notification
Hours of electric boiler ignition before the mainte­
AP011
nance notification with AP010=1
CH operation
AP016
0: Off
1: On
Domestic hot water (DHW)
AP017
0: Off
1: On
Flow temperature setpoint [°C] for manual heat re­
AP026
quest with AP002=1
Outside sensor
0: No outside sensor
AP056
1: AF60
2: QAC34 / IFOS
Maximum temperature setpoint [°C] in heating and
AP063
domestic water mode
188
INIDENS
Press the F2 key or the F3 key until the desired parameter appears,
then press the F4 key to confirm.
Press the F2 – F3 keys to change the value.
press F4 to confirm;
press F1 to exit.
To view/modify the list of settings, it is also possible to connect the
Bluetooth interface to the boiler via the connector X10. Then interface the
handset (SERVICE) to the boiler using the SERVICE TOOL software.
Danger
FOR LOW TEMPERATURE HEATING INSTALLATIONS
MODIFY SETTING CP000 ACCORDING TO THE MAXIMUM
FLOW TEMPERATURE.
Important
The factory settings for certain settings may differ based on the
market the product is destined for.
Factory
value
2
0
0.8
3000
0
17500
1
1
40
1
80
Minimum
Maximum Level
0.6
3.0
0
51,000
0
51,000
10
90
25
90
7804841 - 02 - 20012022