Tab.92
Temperature flow/heating circuit return sensors, DW tank and DW sensor (NTC10K Beta 3977 10 KOhm @ 25 °C)
Temperature [°C]
0
Resistance [Ω]
32505
Tab.93
Heat exchanger protection flue gas temperature sensor (NTC20K Beta 3970 20kOhm @ 25 °C)
Temperature [°C]
0
Resistance [Ω]
66050
— — — — —>
110
— — — — —>
1009
3.3

Dimensions and connections

Fig.93
Key to dimensions and connections
1
Safety valve
2
Heating circuit flow fitting (3/4")
3
Ø 21.8 mm adapter for condensate discharge
4
1/2" Domestic Hot Water (DHW) outlet fitting/3/4" Domestic Hot Water (DHW) tank flow fitting
5
Gas inlet fitting (3/4")
6
Domestic cold water inlet fitting (1/2")
7
Heating circuit return fitting (3/4")
8
Heating system/boiler filling cock
7804841 - 02 - 20012022
10
20
25
19854
12483
9999
10
20
25
40030
25030
20000
120
130
140
768
592
461
30
40
50
8060
5332
3608
30
40
50
16090
10610
7166
150
160
170
364
290
233
1
2
4
3
3 Technical specifications
60
70
2492
1754
60
70
80
4943
3478
2492
180
190
-
189
155
-
8
5
6
7
BO-7798902-1
INIDENS
en
80
90
1257
915
90
100
1816
1344
-
-
-
-
153