SUB-STATUS
Operation at limited temperature setpoint
Operation at required output
Level 1 gradient detected
Level 2 gradient detected
Level 3 gradient detected
Flame protection active
Stabilisation time
Boiler start at minimum output
Operation in heating mode has been interrupted by a domestic hot water request. Restart from power output in which
it was interrupted.
Post ventilation
Fan off
Output reduction due to high flue gas temperature
Pump post circulation
9.5

Reading meters

F1
F2
F3
F4 F4
F3
BO-0000272-3
Tab.120 List of meters (read only)
Meters
Level
AC001
User
AC002
Installer
AC003
Installer
AC004
Installer
AC005
User
AC006
User
AC016
Installer
AC026
Installer
AC027
Installer
CLR
Installer
DC001
Installer
DC002
Installer
DC003
Installer
DC004
Installer
DC005
Installer
GC007
User
PC001
Installer
7804841 - 02 - 20012022
Proceed as described below to access the menu:
Press the F3 - F4 keys together;
The
Press the keys F2 - F3 up to the symbol
confirm;
Press the F2 - F3 keys until you reach the desired counter then press
the F4 key to confirm;
To access the counters at installer level, use the keys F2 - F3 up to the
symbol SVC then press the key F4 to confirm;
Use the keys F2-F3 to enter the code 0012 and confirm by pressing the
F4 key
Press the keys F2-F3 until you reach the desired counter then press the
key F4 to confirm
Press F1 to exit.
Description
Number of boiler power supply hours
Number of boiler operating hours after last maintenance operation
Number of boiler power supply hours after last maintenance operation
Failed start-up attempts after last maintenance operation
Indicative energy consumption [kW/h] in heating mode
Indicative energy consumption [kW/h] in domestic hot water (DHW) mode
Filling counter, counts the amount of filling cycles
Number of pump operating hours
Number of pump start-ups
Resetting of all meters (to be confirmed by pressing the F4 key)
NOTE: This parameter is only displayed if AP010 ≠ 0
Total energy consumption used by domestic hot water (DHW)
Number of domestic hot water cycles (three-way valve switching)
Number of hours in domestic hot water mode (three-way valve switching)
Number of burner start-ups for domestic hot water mode
Number of burner start-up hours for domestic hot water mode
Failed start-up attempts
Indicative electrical energy consumption [kW/h] in heating mode
symbol flashes on the display;
en
9 Settings
31
32
33
34
35
36
37
38
39
41
44
45
60
then press the key F4 to
INIDENS
195