  • Page 1 Fuel oil/gas-fired boilers GT 220 - GT 2200 Installation and Service Manual 300008281-001-E...
  • Page 2 Declaration of conformity CE GT 220 - GT 2200 22/01/09 - 300008281-001-E...
  • Page 3: Table Of Contents

    Contents General .................4 Regulations for France .
  • Page 4: General

    1. General 1 General The boiler shall be assembled and installed by a qualified professional only. For a proper operating of the boiler, follow carefully the instructions. 1.1 Regulations for France Certificate of compliance - NF P 45-204 standards Gas installation, (formerly DTU 61-1, gas installations: April 1982, Only concerns GT 220/2200 boilers fitted with a forced draught addendum no 1: July 1984).
  • Page 5: Description

    2. Description 2 Description 2.1 General Boilers in the GT 220 range have the following characteristics: Boilers in the GT 2200 range have the following characteristics: - Autonomous automatic hot water boilers - Autonomous automatic hot water boilers - Boiler ** CE. - Boiler ** CE.
  • Page 6: Technical Characteristics

    - Flow temperature: 80 °C. - Boiler thermostat setting: 30 - 90 °C - Return temperature: 60 °C. - Setting the safety thermostat: 110 °C - Maximum operating pressure: 4 bar GT 224 GT 225 Boiler type GT 2204 GT 2204...
  • Page 7: Rating Plate

    2. Description Except Belgium 1 mbar = 10 mmCE = 10 daPa = 100 Pa / 1 K =1 °C up to 60 kW up to 70 kW above 70 kW Specific flow: Minimum average rise in temperature of 30K that the appliance can provide in the course of two successive draw-offs of 10 minutes Heat exchanger inlet temperature: 80 °C separated by a stop of 20 minutes.
  • Page 8: Main Dimensions

    2. Description 2.6 Main dimensions 2.6.1 Boiler and tank dimensions • GT 220 • GT 2200 GT 2204/160 GT 2205/160 GT 224 GT 225 GT 226 GT 227 GT 228 GT 2204/250 GT 2205/250 1081 1208 1026 1153 1280 Ø...
  • Page 9: Installation Dimensions

    Keep space free around the boiler to ensure good accessibility to the appliance. Minimum recommended dimensions (in mm): • GT 220 • GT 2200 Boiler A (mm) Boiler A (mm) GT 224 GT 2204/160 GT 225 GT 2204/250 1306 GT 226 GT 2205/160 GT 227 1081 GT 2205/250...
  • Page 10: Aeration

    2. Description 2.7 Aeration Position the air inlets in relation to the high ventilation vents in order Do not obstruct the air inlets in the room (even partially). that the air is refreshed throughout the boiler room. 2.7.1 If using fuel oil Generator installed in a builing for individual use The minimum cross sections and the emplacement of the fresh air inlet and the air discharge are governed by the order of 21/03/1968...
  • Page 11: Installation

    3. Installation 3 Installation 3.1 Mounting See: Boiler installation instructions. 3.2 Hydraulic connections Installation must be carried out in accordance with the prevailing for GT 2200: Before making the connection to the heating regulations, the codes of practice and the recommendations in these installation, carry out the assembly and connection instructions.
  • Page 12 3. Installation 3.2.3 Typical systems The following diagrams are given by way of an example. Other connections may be made. Key to the diagrams Heating outlet Heating return 3-bar safety valve Pressure gauge Automatic air vent Valve 3-way mixing valve Heating pump Expansion vessel Draining valve...
  • Page 13 3. Installation Installation with 1 direct radiator heating circuit (without mixing valve) Control panels possible for this type of installation: • 1-stage burner: - Control panel B - Control panel D (DIEMATIC 3), • 2-stage burner - Modulating burner: - Control panel B2 - (2 stages) - Control panel D (DIEMATIC 3) + PCB 2-stage burner / modulating burner / 3-way valve - Package AD217.
  • Page 14 3. Installation Installation with 1 direct heating circuit (radiator) and 1 circuit with mixing valve (radiators or underfloor heating) • 1-stage burner: This type of installation must be controlled by the Diematic 3 panel plus the "mixing valve PCB" option (Package FM 48) •...
  • Page 15 3. Installation Installation with 1 swimming pool heating circuit and 1 circuit with mixing valve (radiators or underfloor heating) • 1-stage burner: This type of installation must be controlled by the Diematic 3 panel plus two "DHW sensor" options (package AD 212) and the "mixing valve PCB + sensor"...
  • Page 16 3. Installation Heating installation with 1 direct heating circuit (radiator) and 2 circuits with mixing valve (radiators or underfloor heating) • 1-stage burner: This type of installation must be controlled by the Diematic 3 panel plus the two "mixing valve PCB + sensor" options (package FM 48) and the "DHW sensor"...
  • Page 17: Chimney Connection

    Boiler type Smoke nozzle Ø A GT 224 - GT 225 Ø 153 GT 226 - GT 227 - GT 228 Ø 180...
  • Page 18: Connecting The Burner

    3. Installation 3.4 Connecting the burner 3.4.1 Dimensions for fitting the burner B = Drilling Ø 110, Precut Ø 130. C = 4 x M8 on Ø 150, 4 markings on Ø 170. 3.4.2 Burner location The position of the burner head in relation to the door insulation must be respected.
  • Page 19: Filling The Installation With Water

    3. Installation 3.6 Filling the installation with water Heating circuit GT 220 - GT 2200 DHW tank exchanger GT 2200 Fill slowly via the low point on the heating installation: For the bleeding of the DHW tank exchanger to be done correctly, proceed as follows: - Either via the filling and draining valve (see drawing above).
  • Page 20: Maintenance

    4. Maintenance 4 Maintenance 4.1 Checking and cleaning the main components 4.1.1 Water level Regularly check the level of water in the installation. Top it up, if need Do not drain the installation, except in cases of absolute be, avoiding the abrupt input of cold water into the hot boiler. If this necessity.
  • Page 21 4. Maintenance 4.2.1 Sweeping the boiler Manual sweeping Disconnect the burner cable. Unscrew the 2 flanged nuts with flat washers. Open the door of the combustion chamber. - Remove the baffle plates (number variable depending on the boiler model). - Carefully sweep the flue ways with the brush supplied for that purpose.
  • Page 22: Chemical Sweeping

    4. Maintenance Chemical sweeping A. General principle Boilers are traidtionally swept mechanically. There are now chemical sweeping methods which facilitate this maintenance work. A chemical reagent is applied to the boiler's heating surfaces. After application, the reaction is completed by igniting the burner. The initial deposits are neutralised and pyrolised.
  • Page 23: Burner

    4. Maintenance E. Cleaning - Remove the baffle plates (number variable depending on the boiler model). - Light sweeping will remove the pulverent residues remaining after combustion. The remaining pulverent residues are easy to remove by sweeping or vacuum cleaning. For certain products, brief application after cleaning has a preventive effect, limiting deposits on the heating surfaces.
  • Page 24: Stopping The Boiler

    5. Stopping the boiler 5 Stopping the boiler Precautions to take if there is a danger of frost Heating circuit: Use a correctly dosed antifreeze to prevent the heating water freezing. If this cannot be done, drain the system completely. In all cases, consult the fitter.
  • Page 25: Spare Parts - Gt 220 - Gt 2200

    6 Spare parts - GT 220 - GT 2200 22/01/09 - 300008281-002-E The code number on the list next to the required piece must be stated when ordering replacement parts. See also: - Control panel instructions: X,B, B2, E, ER, E1, E1R, D, D + AD217. - Burner instructions - Domestic hot water calorifier instructions (GT 2200).
  • Page 26 6. Spare parts - GT 220 - GT 2200 Casing + insulation GT 220 M000429B M000429B GT 220 - GT 2200 22/01/09 - 300008281-001-E...
  • Page 27 Complete casing - 6 sections 8227-5503 Pipe kit + Plug 200004877 Complete casing - 7 sections 8227-5506 Assembly rod 440 mm - M8 - GT 224 200004878 Complete casing - 8 sections 8227-5507 Assembly rod 440 mm - M8 - GT 225 200004624...
  • Page 28 © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 22/01/09 DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30...