EtherCAT Slaves (Excluding Six-port Junction Slaves)
 PLC Box
Set the PLC box as follows.
ID
20161
Configuration project
20408
Station ID
20253 1
CPU: Name [1]
20418
Version
 Bus Ports (EtherCAT Ports)
Set EtherCAT ports (input ports) as follows.
ID
20311
Physical network: Bus ID /
item number
(a)
NX-ECC203
Precautions for Correct Use
To import EtherCAT slaves, you need to set this as follows.
• Place the EtherCAT slaves in the Schematic single-line page.
• Set the node addresses so that they do not conflict with other slaves.
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)
Property name
Same value as "Configuration project" of the CPU Unit
Any name in a format that meets the EPLAN specification con-
straints and is different from "Station ID" of other component
data
Same value as "CPU: Name [1]" of the CPU Unit
Revision of the EtherCAT slave (This must be a version that
exists in the Sysmac Studio and a single-byte number that con-
tains periods as the delimiter.)
If blank, the component data will be imported with the latest
version.
Property name
(a): EtherCAT node address (Set a single-byte number within
the node address range of the CPU Unit that can be set.)
3 Setting EPLAN Electric P8
Setting value
Setting value
3
3-9