2 Target Data and Preconditions for the Sysmac Studio/EPLAN Electric P8 Connector Function
2-2
Preconditions for the Sysmac Studio/
EPLAN Electric P8 Connector Func-
tion
This section describes the preconditions for using the connector function and the preconditions for im-
porting the target data.
Additional Information
Refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504) for the conditions for
the Sysmac Studio to import data.
2-2-1

Preconditions for Using the Connector Function

All of the following conditions must be met to use the connector function.
• In an EPLAN Electric P8 project, the CPU Unit is supported by the connector function. Refer to
2-1-1 CPU Units on page 2-2 for the CPU Unit models supported by the connector function.
• In the EPLAN Electric P8 project, the component data and project settings for the CPU Unit meet
the conditions of the property setting values described in 3-2-1 CPU Units on page 3-3 and
3-3-1 CPU Units on page 3-8.
• There is only one CPU Unit in the data to export from EPLAN Electric P8 to the AML file.
2-2-2

Preconditions for Importing Target Data

This section describes the import preconditions for target items in a controller configuration and device
variables.
Preconditions for Importing EtherCAT Slaves
All of the following conditions must be met to import EtherCAT slaves in the Sysmac Studio.
• In an EPLAN Electric P8 project, the EtherCAT slaves are supported by the connector function. Re-
fer to 2-1-2 EtherCAT Slaves on page 2-2 for the EtherCAT slave models supported by the connec-
tor function.
• In the EPLAN Electric P8 project, the component data and project settings for the EtherCAT slaves
meet the rules described in 3-2-2 EtherCAT Slaves on page 3-3 and 3-3-2 EtherCAT Slaves on
page 3-8.
Preconditions for Importing an NX Unit Configuration
All of the following conditions must be met to import an NX Unit configuration with the Sysmac Studio.
• In an EPLAN Electric P8 project, the NX Unit configuration consists of only Units supported by the
connector function. Refer to 2-1-3 NX Units on page 2-4 for the NX Unit models supported by the

connector function.

• In the EPLAN Electric P8 project, the component data and project settings for the NX Units meet the
rules described in 3-2-3 NX Units on page 3-6 and 3-3-3 NX Units on page 3-10.
2-8
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)