2 Target Data and Preconditions for the Sysmac Studio/EPLAN Electric P8 Connector Function
Creating a new project
Importing the AML file
Performing the Configura-
tions and Setup and pro-
gramming
2-3-2

Correcting Device Variable Assignments

Perform the following procedure after completing Creating a Project.
1
Correct device variable assignments in EPLAN Electric P8.
Correcting the project
2
Export the controller configuration and device variables from EPLAN Electric P8 to an AML file.
Exporting the AML file
3
Import the AML file to the Sysmac Studio.
Importing the AML file
Checking the program
2-3-3

Correcting Device Variable Comments

Perform the following procedure after completing Creating a Project.
1
Correct device variable comments in EPLAN Electric P8.
Correcting the project
2
Export the controller configuration and device variables from EPLAN Electric P8 to an AML file.
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)
What to do
Create a new project with the target
CPU Unit model and version.
Import the controller configuration
and device variables using the con-
troller configuration and device vari-
able import function.
Start designing the control system.
What to do
Correct device variable assign-
ments in the electrical drawing
project. (For example, swap the de-
vice variables assigned to two I/O
terminals.)
What to do
Export the AML file used for the
connector function.
What to do
Changes in device variables will be
merged through importing device
variables.
Check if the changed device varia-
ble assignments have any impact
on the program.
What to do
Change device variable comments
in the electrical drawing project.
Description
Refer to the Sysmac Studio Version
1 Operation Manual (Cat. No.
W504).
Description
Section 3 Setting EPLAN Electric
P8 on page 3-1
Description
3-4 Setting the AML File Export on
page 3-15
Description
Refer to the Sysmac Studio Version
1 Operation Manual (Cat. No.
W504).
Description
Section 3 Setting EPLAN Electric
P8 on page 3-1
Reference
Reference
Reference
Reference
Reference
2-11