NX Units in a CPU Rack Configuration
 PLC Box
Set the PLC box as follows.
ID
20161
Configuration project
20408
Station ID
20427
Rack ID
20410
PLC card is placed on rack ID
20411
Position (slot / module)
20253 1
CPU: Name [1]
20418
Version
*1.
For Safety CPU Units, Safety Digital Input Units, and Safety Digital Output Units, leave the properties
blank.
Precautions for Correct Use
To import an NX Unit configuration, you need to set this as follows.
• Set NX Unit numbers so that they do not conflict in the CPU Rack configuration.
• Set NX Unit numbers so that they are sequential numbers that start from 1.
NX Units in a Slave Terminal Configuration
 PLC Box
Set the PLC box as follows.
ID
20161
Configuration project
20408
Station ID
20427
Rack ID
20410
PLC card is placed on rack ID
20411
Position (slot / module)
20253 1
CPU: Name [1]
20418
Version
*1.
For Safety CPU Units, Safety Digital Input Units, and Safety Digital Output Units, leave the properties
blank.
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)
Property name
Same value as "Configuration project" of the CPU Unit
Same value as "Station ID" of the CPU Unit
Blank
Same value as "Rack ID" of the CPU Unit
NX Unit number (This must be a single-byte number.)
Same value as "CPU: Name [1]" of the CPU Unit
Unit version (This must be a version that exists in the Sysmac
Studio and a single-byte number that contains periods as the
delimiter.)
If blank, the component data will be imported with the latest
version.
Property name
Same value as "Configuration project" of the CPU Unit
Same value as "Station ID" of the EtherCAT Coupler Unit to
which the NX Unit belongs
Blank
Same value as "Rack ID" of the EtherCAT Coupler Unit
NX Unit number (This must be a single-byte number.)
Same value as "CPU: Name [1]" of the CPU Unit
Unit version (This must be a version that exists in the Sysmac
Studio and a single-byte number that contains periods as the
delimiter.)
If blank, the component data will be imported with the latest
version.
3 Setting EPLAN Electric P8
Setting value
*1
Setting value
*1
3
3-11