Installing The Card - AMD XILINX T2 Telco Installation Manual

Hide thumbs Also See for XILINX T2 Telco:
Table of Contents

Advertisement

• Verify that the minimum card space is available to install your card.
• Check for card compatibility with your system. Check system requirements such as power, bus
type, and physical dimensions to support the card.

Installing the Card

The following procedure is a guide to T2 Telco accelerator card PCI x16 installation. Consult your
computer documentation for additional information.
Note: This procedure is for use with UL Listed Servers or ITE.
1. Ensure that the host power supply is disconnected.
2. If you are working with an enclosed computer, open your computer by removing the casing.
3. If necessary, remove the adjacent PCIe slot cover corresponding to the PCIe slot in which you
are installing the card.
4. Plug the T2 card into the bifurcated PCIe x16 slot on the motherboard.
Note: There is no auxiliary power connector on the T2 card.
Note: There is also a USB JTAG connector that can be connected from the server to the T2 card. It can
be used to program the flash. This is for development purposes and is not intended for use in a
production setting.
UG1527 (v1.0) June 15, 2022
T2 Telco Accelerator Card Installation Guide
Chapter 2: Card Information and Installation
Send Feedback
www.xilinx.com
11