2. Verify the SC firmware version. Execute ./sc_flash.sh get_sc_fw_version. A
possible successful output is shown below:
SC fw version: 01.02.00
3. Bring the card in FW_AVAILABLE mode. For the first time, execute ./sc_flash.sh
<image_name> <bsl_password_file>. The expected output is as follows:
"Please reboot the Host and re-run the command"
4. Reboot the host.
5. Program the SC image. For the second time, execute ./sc_flash.sh <image_name>
<bsl_password_file>.
Running host Application
Fw upgrade started
Fw image Data > @0[16]
Fw image Data > @200[16]
Fw image Data > @1AE20[16]
Fw image Data > @3F000[16]
[flash_mem_sections] : 4
BslPasswordSize:56
Programming SC firmware image... (100%)
Programmed SC firmware image done successfully
6. During the upgrade, the SC state should be FW_UPDATE, as shown below.
SC is in FW_UPDATE mode
Execute ./sc_flash.sh get_sc_state.
UG1527 (v1.0) June 15, 2022
T2 Telco Accelerator Card Installation Guide
Chapter 4: T2 Factory Installed Image
www.xilinx.com
Send Feedback