Connecting To The Diagnostic Pc - HAKO Scrubmaster B 260 R Service Booklet

Hide thumbs Also See for Scrubmaster B 260 R:
Table of Contents

Advertisement

2.3 Diagnostics and communication
2.3.3 Connection to the diagnostic PC
Ensure that the –A01 control unit has been fully installed in the machine before
activating the backup battery. To do this, remove the insulating strip between the
battery (CR2032) and the battery holder on the control unit.
Connect the interface (* / **) to a free USB port of the service PC.
Establish a connection between the machine and the diagnostic computer using
the diagnostic cable (PN 03502750) and the interface (PN 03502430 or
03501750).
Connect the OBD connector (blue contact protection) of the diagnostic cable to the
OBD contact of the machine (located behind the cover in the steering column).
• Connecting the machine controller to –A01.X20 with the serial cable
automatically leads to activation of the Fleet recorder option. The machine
is not operational if the Fleet recorder is not connected. In this case the
"Fleet recorder" option must be deactivated (Chapter 12 – Options).