Motorola SABER I User Manual page 31

Table of Contents

Advertisement

2.
PowerLevel
Four
dilferent power
levels
can be
adjusted
in
the
SABER radio
-
the
!ow,
medium,
high,
and
specialpower levels. (Each channe! in the
radio
can
have
unique power level assQnments
made on
the Radio Channel lnlormation screen described in
Sectaon
Vlll-C. ) Note that the
standard low and
hBh power settings for
UHF
are 2.0W
to 5.0W
respectively,
and
for
VHF
the
power
settings are 2.5W
to
6.0W respectively. Even though these are the standard
settings, you
can
set
the
power levels
to
any value
up
to the
maxirnum
setting
allowed.
Note
that you can set both the low and high power
levels
lo
the same value if you wish, which
allows both settings
to
have either
a
low power
Setting,
a high power setting, or any power
levelupto
the
maximum level allowed.
Use
the ENTER
key
to
selest
the power setting
you
wish
to adiust: LOW MEDIUM,
HIGH,
or
SPECIAL.
Orrce
you.have
sebaed
the
appropriate
power
letel,
(the
selected power
level
settarp
willbe
hBhlightect
in
inverse
video),lollow
the procedure given
below. When aligning
the
Power Level,
you can check the power outprjt dudng the alignment process
or
in
"real
time.'
You
do
not have
lo
reprogram
the
radio to see
the
immediate power change.
(a)
Fotlow
the
Setup Procedure in Section
Vl-A,
Fig. 8.
(b)
Before aligning
the power level, select the proper TOGGLE POWER
BIAS
with
the
F7
function
key according to the
table
below:
Select
Power Bias High:
>
2
W
for
High power radios
Selec{ Power Bias Low:
<
2
W.lor
High power radios
OR
>
1
W lor
Low power
radios
<
1
W.lor
Low power radios
(c)
choose a
channel
with
a
frequency
as close
to
the center of
the
band as
possible.
or
the
center
lrequency
o,
the
radio to
be
aligned.
Set
the
radio to that channel.
(d)
Connect
the
RF BNC connector
to an
RF power
meter.
(e)
Key
upthe
radio
and
measure
the
RF power.
(f)
De-key
the
radio and use the arrow keys to adjust the power
to the
desired power
setting. The
UP
anow key (or
PGUP)
will
increase
the power level setting value if the
measured power
is
lower
than the desired
value
while
the
DOWN
arrow key (or
PGDN)
wil! decrease
the power level value
il the
meaiured power is higher than the desired
value.
(g)
Re-key
the
radio
and
measure
the
output
power.
(h)
Repeat
the
procedure until the
power
level is
at
the
desired
level.
(i)
Check
power output at the band edges (by going to the channel closest to the band
edges) to ensure
that you
meet
the
power requirements at
those lrequencies.
ll
required,
retum
to the
center lrequency and adjust
the power so that you meet the requiremenl
across
the
band.
once you
have completed one
ol the
power level sening adjustments, select
the other power
levelsetling
and repeat
lhe
above procedure to obtain
the
desired
power
setting.
24