Network Configuration; Permissible Network Topologies - Siemens SINUMERIK 840D sl TCU 30.3 Manual

Hide thumbs Also See for SINUMERIK 840D sl TCU 30.3:
Table of Contents

Advertisement

5.3

Network configuration

5.3.1

Permissible network topologies

Ethernet connection
A SINUMERIK 840 D sl can only be operated as a network within which the individual
components communicate with one another via Ethernet connections. This network must be
set up.
The individual components are factory-set so that the most frequently occurring standard
configurations can be operated without changing the settings related to the network.
Division into system network and company network
On the SINUMERIK solution line, the components are generally split into a company network
on the one hand and a system network on the other.
The connection to the company network provides access to the network drives, for example.
On the system network, process data communication and image transmission runs from the
components with operator software to the display units – the respective TCU.
This split is performed physically by means of the prescribed use of the Ethernet interfaces on
the components:
● A TCU is connected exclusively to the system network.
● An NCU is always connected to the system network via X120.
● Ethernet interface Eth 2 of the PCU is preconfigured for connection to the system network;
while Ethernet interface Eth 1 is used for connection to the company network.
● An NCU is connected to the company network via X130.
Meaning of the connections:
Green connection
Gray connection
TCU 30.3
Manual, 09/2017, A5E40874197
Eth 1 as a DHCP client
Eth 2 as a DHCP server
Eth 2 with a fixed IP address
Uncrossed Ethernet cable
Crossed Ethernet cable (crossover)
Networking
5.3 Network configuration
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents