C
LEANING
Cleaning the ribbon path
All parts which come into contact with the ribbon [22]
must be cleaned on a regular basis. The following min-
imum distances apply:
•
Once per week
or
•
Every 5000 m of ribbon
Operating manual ALX 73x | file version 00 | 04/2011
C
[22] Parts where ribbon residue gathers:
A Ribbon roller
B Deflector roller + stress relief
C Deflector
D Deflector tab on printhead
ALX
73x
GB
A
B
D
Cleaning the ribbon path | 14