MMI-20027478
Figure 4-14: Internally powered frequency output: output amplitude versus load
resistance [24 VDC (Nom) open circuit]
A. Output amplitude (V)
B. Load resistor (Ω)
4.5.4
Wire the frequency output (externally powered Channel
D)
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-15: Frequency output wiring (externally powered)
A
A. Frequency output
B. 3–30 VDC (maximum)
C. 500 mA current (maximum)
D. Signal device