Chapter 1: Power Delivery Network (PDN) Tool User Guide for Stratix IV Devices
Major Tabs of the PDN Tool

X2Y Mount

The X2Y Mount tab, shown in
inductance seen by the X2Y decoupling capacitor.
Figure 1–6. X2Y Mount Tab
You enter all the information relevant to your layout and the tool provides a
mounting inductance for a X2Y capacitor mounted on either the top or bottom layer
of the board. As with the other tabs, you can save the changes made to the tab, restore
the changes, and restore the tab back to the default settings.
© March 2009 Altera Corporation
Figure
1–6, is used to calculate the capacitor mounting
Power Delivery Network (PDN) Tool for Stratix IV Devices User Guide
1–9