Data Report; Example Of Reportdatacmd - netvox R718T User Manual

Wireless push button interface
Hide thumbs Also See for R718T:
Table of Contents

Advertisement

5. Data Report

When the device is turned on, it will immediately send a version package.
Data will be reported once per hour by default setting.
Default setting:
Maximum time: 3600s
Minimum time: 3600s (Detect the current voltage value every 3600s by default setting)
Battery Change: 0x01 (0.1V)
Note:
1. The device report interval will be programmed based on the default firmware which may vary.
2. The interval between two reports must be the minimum time.
3. Please refer Netvox LoRaWAN Application Command document and Netvox LoRa Command
Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Data report configuration and sending period are as following:
Min. Interval
(Unit:second)
Any number
between 1~65535

5.1 Example of ReportDataCmd

FPort:0x06
Bytes
1
Version
Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version
DeviceType– 1 byte – Device Type of Device
ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype
NetvoxPayLoadData– Fixed bytes (Fixed =8bytes)
Max. Interval
(Unit:second)
Any number
between 1~65535
1
DeviceType
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc
Reportable Change
Can not be 0.
1
ReportType
5
to resolve uplink data.
Current Change≥
Reportable Change
Report
per Min. Interval
Var(Fix=8 Bytes)
NetvoxPayLoadData
Current Change<
Reportable Change
Report
per Max. Interval