netvox R718KA2 User Manual

netvox R718KA2 User Manual

Wireless 2-input ma current meter interface
Hide thumbs Also See for R718KA2:

Advertisement

Quick Links

R718KA2
Model:
Wireless 2-Input mA Current Meter Interface, 4~20 mA
Wireless 2-Input mA Current Meter Interface,
4~20 mA R718KA2
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for netvox R718KA2

  • Page 1 R718KA2 Model: Wireless 2-Input mA Current Meter Interface, 4~20 mA Wireless 2-Input mA Current Meter Interface, 4~20 mA R718KA2 User Manual...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction................................2 2. Appearance................................. 3 3. Main Features................................3 4.Set up Instruction.................................4 4.1 Power on and Turn on / off..........................4 4.2 Join Into LoRa Network...........................4 4.3 Function Key..............................4 4.4 Data Report...............................5 5. Restore to Factory Setting............................5 6.
  • Page 3: Introduction

    Introduction R718KA2 is a 2-way current detection device for Netvox ClassA type devices based on LoRaWAN open protocol. The device is suitable for detecting 4mA to 20mA current, and R718KA2 is compatible with LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption.
  • Page 4: Appearance

    2. Appearance Fig.1 R718KA2 Appearance 3. Main Features  Compatible with LoRaWAN protocol.  Powered by 2 x ER14505 3.6V Lithium AA battery  After connecting the detection pin to the detection port, press the device button to report a command carrying the current value.
  • Page 5: Set Up Instruction

    The green indicator will stay on for 5 seconds to show it joins into the network, otherwise, the green indicator will be off. (2) If R718KA2 had been joined into a LoRa network, remove and insert the batteries; it will repeat step (1).
  • Page 6: Data Report

    1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED flashes quickly 20 times. 2. R718KA2 is at off mode by default setting after restoring to factory setting. Note: The device operation of turning off is the same as the “Restore Factory Settings” operation.
  • Page 7: Low Voltage Alarming

    (B) When it is not in the network → R718KA2 will enter sleeping mode and wake up every 15 seconds to search a network to join in the first two minutes. After two minutes, it will wake up every 15 minutes to request to join the network.
  • Page 8 All of the above suggestions apply equally to your device, battery and accessories. If any device is not working properly. Please take it to the nearest authorized service facility for repair.