5. Data Report

The device will immediately send a version packet report and a data report including voltage.
The device sends data according to the default configuration before any other configuring.
Default Setting:
MaxTime: Max Interval = 60 min =3600s
MinTime: Max Interval = 60min = 3600s
BatteryChange = 0x01 (0.1v)
ADCRawValue Change = 0x64 (100 mV) // configuration need to greater than 0x50 (80mV)
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
3. If there are special customized shipments, the setting will be changed according to customer's requirements.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit: second)
Any number between
1~65535
to resolve uplink data.
Max Interval
(Unit: second)
Any number between
1~65535
Reportable Change
Reportable Change
Can not be 0
5
Current Change<
Current Change≥
Reportable Change
Report
per Min Interval
Report
per Max Interval