netvox DirekTronik R718KA User Manual

netvox DirekTronik R718KA User Manual

Wireless ma current meter interface, 4~20ma
Hide thumbs Also See for DirekTronik R718KA:

Advertisement

Quick Links

R718KA
Model:
Wireless mA Current Meter Interface, 4~20mA
Wireless mA Current Meter Interface, 4~20mA
R718KA
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for netvox DirekTronik R718KA

  • Page 1 R718KA Model: Wireless mA Current Meter Interface, 4~20mA Wireless mA Current Meter Interface, 4~20mA R718KA User Manual...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction................................2 2. Appearance................................. 3 3. Main Features................................3 4.Set up Instruction.................................4 4.1 Power on and Turn on / off..........................4 4.2 Join Into LoRa Network...........................4 4.3 Function Key..............................4 4.4 Data Report...............................5 5. Restore to Factory Setting............................5 6.
  • Page 3: Introduction

    Introduction R718KA is a current detection device for Netvox ClassA type devices based on LoRaWAN open protocol. The device is suitable for detecting 4mA to 20mA current, and R718KA is compatible with LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption.
  • Page 4: Appearance

    2. Appearance Fig.1 R718KA Appearance 3. Main Features  Compatible with LoRaWAN protocol.  Powered by 2 x ER14505 3.6V Lithium AA battery  After connecting the detection pin to the detection port, press the device button to report a command carrying the current value.
  • Page 5: Set Up Instruction

    4.Set up Instruction 4.1 Power on and Turn on / off (1) Power on: Insert batteries: open the battery cover; insert two sections of 3.6V ER14505 AA batteries and close the battery cover. (2) Turn on: if the device had never joined in any network or at factory setting mode, after powering on, the device is at off mode by default setting.
  • Page 6: Data Report

    4.4 Data Report When the device is turned on, it will immediately send a version package. Data will be reported once per hour by default setting. Maximum time: 3600s Minimum time: 3600s (Detect the current voltage value every 3600s by default setting) Default reportchange: Battery ---- 0x01 (0.1V) Note:...
  • Page 7: Low Voltage Alarming

    (During this period, if the reportchange is larger than setting value, it will wake up and send a data report). (B) When it is not in the network → R718KA will enter sleeping mode and wake up every 15 seconds to search a network to join in the first two minutes. After two minutes, it will wake up every 15 minutes to request to join the network.
  • Page 8 not working properly. Please take it to the nearest authorized service facility for repair.

Table of Contents