netvox R718CT2 User Manual

netvox R718CT2 User Manual

Wireless thermocouple interface for t/k/r type thermocouple
Hide thumbs Also See for R718CT2:

Advertisement

Quick Links

R718CT2/CK2/CR2
Mode:
Wireless Thermocouple Interface for T/K/R Type Thermocouple
Wireless Thermocouple Interface for
T/K/R Type Thermocouple R718CT2/CK2/CR2
User Manual

Advertisement

loading

Summary of Contents for netvox R718CT2

  • Page 1 R718CT2/CK2/CR2 Mode: Wireless Thermocouple Interface for T/K/R Type Thermocouple Wireless Thermocouple Interface for T/K/R Type Thermocouple R718CT2/CK2/CR2 User Manual...
  • Page 2: Table Of Contents

    It is not recommended for use in weak oxidizing atmospheres in oxidizing alternating atmospheres and in vacuum. R718CT2 (copper-copper-nickel thermocouple): its use temperature is , it is used in the temperature range of , and the stability is -40 ~ +125℃...
  • Page 3: Appearance

     Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices /Cayenne  Low power consumption, longer battery life support*: Battery life is determined by sensor reporting frequency and other variables, please refer to http://www.netvox.com.tw/electric/electric_calc.html On the website, users can find battery life of various models in different configurations.
  • Page 4: Set Up Instruction

    4.Set up Instruction On/Off Insert batteries. Power on (users may need a flat blade screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off Press and hold the function key for 5 seconds till green indicator flashes for 20 times. (Restore to factory setting) Power off Remove Batteries.
  • Page 5: Data Report

    5. Data Report The device will immediately send a version package report and a report data with temperature and humidity and voltage values. The device sends data in the default configuration before any configuration is done. Maximum time: Max Interval (default 900 seconds) Minimum time: Min Interval (default 900 seconds) (by default, the current voltage value is detected per Min Interval) Default reportchange: Battery --- 0x01 (0.1V)
  • Page 6: Installation

    Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Users push the button, Wakes up and collects data REPORTS 3.5V. Wakes up and collects data 3.5V |3.5-3.6|=0.1 Recalculate MaxTime. 3.5V Does not report REPORTS 3.5V sleeping sleeping...

This manual is also suitable for:

R718ck2R718cr2