Data Report - netvox R718J User Manual

Wireless dry contact interface
Hide thumbs Also See for R718J:
Table of Contents

Advertisement

Function Key
Press and hold for 5 seconds
Press once
Sleeping Mode
The device is on and in the
network
Low Voltage Warning
Low Voltage

5. Data Report

When the device is turned on, it will immediately send a version package.
Data will be reported once per hour by default setting.
Default Setting:
Maximum Time: 0x0E10 (3600s)
Minimum Time: 0x0E10 (3600s)
Battery Change: 0x01 (0.1V)
LastMessageResendTime: 0x00
Dry Contact Detection Trigger:
When the dry contact is connected, the data status bit is "1".
When the dry contact is disconnected, the data status bit is "0".
Last Message Resend Time Function:
Resendtime = 0x00 or 0xFF, send the current dry contact state
Resendtime = 0x03 to 0xFE, send the current dry contact state, and re send the dry contact state after 3-254s
*The function of Resendtime is supported by the firmware version after 2020/05/13 version
Note:
The device send data cycle depends on real burning configuration.
The interval between two reports must be the minimum interval.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/cmddoc
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report
according to Min Interval.
3.2V
// Detect the current voltage value every 3600s by default setting
to resolve uplink data.