Download Print this page
netvox R718T2 User Manual

netvox R718T2 User Manual

Wireless 2-input push button interface
Hide thumbs Also See for R718T2:

Advertisement

Quick Links

Model:R718T2
Wireless 2-Input Push Button Interface
Wireless 2-Input Push Button Interface
R718T2
User Manual

Advertisement

loading

Summary of Contents for netvox R718T2

  • Page 1 Model:R718T2 Wireless 2-Input Push Button Interface Wireless 2-Input Push Button Interface R718T2 User Manual...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction................................2 2. Appearance................................. 3 3. Main Features................................3 4.Set up Instruction.................................4 4.1 Power on and Turn on / off..........................4 4.2 Join Into LoRa Network...........................4 4.3 Function Key..............................4 4.4 Data Report...............................5 5. Restore to Factory Setting............................5 6.
  • Page 3: Introduction

    The Wireless 2-Input Push Button Interface allows a notification signal to be sent when connected push button is pushed. When someone is in danger and needs emergency assistance, press the emergency push button device; R718T2 immediately sends an alarm message to the gateway. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption.
  • Page 4: Appearance

    2. Appearance Fig.1 R718T2 Appearance 3. Main Features  Compatible with LoRaWAN protocol.  Powered by 2 x ER14505 3.6V Lithium AA battery  To detect on or off signal of two way emergency switch button  Easy set up and installation...
  • Page 5: Set Up Instruction

    The green indicator will stay on for 5 seconds to show it joins into the network, otherwise, the green indicator will be off. (2) If R718T2 had been joined into a LoRa network, remove and insert the batteries; it will repeat step (1).
  • Page 6: Data Report

    1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED flashes quickly 20 times. 2. R718T2 is at off mode by default setting after restoring to factory setting. Note: The device operation of turning off is the same as the “Restore Factory Settings” operation.
  • Page 7: Low Voltage Alarming

    (B) When it is not in the network → R718T2 will enter sleeping mode and wake up every 15 seconds to search a network to join in the first two minutes. After two minutes, it will wake up every 15 minutes to request to join the network.